8. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
Remote Control Power Consumption
While the Engine Switch is in the "RUN" (I) position
and the battery power restore switch has been
pressed for about 3 seconds, the remote module is
active and waiting for signal. This function requires
electrical current which is consuming the battery.
THIS
GENERATOR
DISCONNECT THE BATTERY AFTER 12 HOURS
TO
AVOID
BATTERY
GENERATOR IS NOT RUNNING AND THE
ENGINE SWITCH IS LEFT IN "RUN" (I) POSITION.
YOU
MUST
GO
PROCEDURE TO RESUME RUNNING THE UNIT
Connecting Electrical Loads
AGAIN.
This unit has been pretested and adjusted to
handle its full capacity. Before starting the
generator, disconnect all load. Apply load only
after generator is running. Voltage is regulated via
the engine speed adjusted at the factory for
correct output. Readjusting will void warranty.
CAUTION
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the
amperage rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
1.Let engine stabilize and warm up for a few
minutes after starting.
2.Ensure circuit breaker on control panel is in
position.
3.Plug in and turn on the desired 120 Volt AC,
single phase, 60Hz electrical loads. It is
to attach the item with largest load first.
English
FIRMAN1Page 25
WILL
AUTOMATICALLY
DRAINAGE,
IF
THROUGH
STARTING
better
Connecting a generator to your electric utility
company's power lines or to another power source
may be against the law. In addition this action, if
THE
done incorrectly, could damage your generator and
appliances and could cause serious injury or even
death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage,
please
notify
immediately
appliances directly into the generator. Do not plug
the generator into any electric outlet in your home.
Doing so could create a connection to the utility
company power lines. You are responsible for
ensuring that your generator's electricity does not
feed back into the electric utility power lines. If the
generator will be connected to a building electrical
system, consult your local utility company or a
qualified electrician. Connections must isolate
generator power from utility power and must
comply with all applicable laws and codes.
Economy Control Switch
The Economy Control switch can be activated in
order to minimize fuel consumption and noise while
operating the unit during times of reduced electrical
output, allowing the engine speed to idle during
on
periods of non-use. The engine speed returns to
normal when an electrical load is connected. When
the economy switch is off, the engine runs at normal
speed continuously.
your
electric
utility
and
remember
to
Customer Service: 1-844-
company
plug
your