Technical Data
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
anti-pollution function
The hot and cold supplies must be of equal
pressures.
To adjust the hot water limiter on single lever
mixers, please see page 7.
No adjustment is necessary when using a
continuous flow water heater.
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
Spare parts see page 3
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
selector
6
aerator
7
non return valve
8
hose
9
shower holder, assy
10
hand shower
XXX = Colors
000 chrome plated
810 satinox®
6
max. 1 MPa
0,1 – 0,5
1,6 MPa
max. 80° C
65° C
22 l/min 0,3 MPa
10093XXX
96762000
96763XXX
97209000
92730000
96294000
96296XXX
94074000
28282XXX
96295000
28531XXX