Technical Details :
- Power supply
- Flashing beacon output
- Motor output
- Auxiliary power output
- Stop limit and low voltage commands : 24 Vcc
- Working temperature
- Radio receiver
- Op. transmitters
- Max stored TX codes
- Box dimensions
- Container Module DIN
List of connections :
CN1 :
1 : 230 V ac line input (Phase).
2 : 230 V ac line input (Neutral).
3 : 230 V ac flashing line input (Neutral).
4 : 230 V ac flashing line input (Phase).
5 : Opening motor output.
6 : Common motor output.
7 : Closing motor output.
CN2:
1 : Service power supply output 24Vac 6 W.
2 : Service power supply output GND.
3 : Open-close command button input (NO).
4 : Common GND input.
5 : Safety device input (NC).
6 : Opening stop limit input (NC).
7 : Common GND input.
8 : Closing stop limit input (NC).
9 : Earth antenna input.
10: Antenna hot pole input.
: 230 Vac 50/60Hz 900W(4A) max.
: 230 Vac 50/60Hz
100W Resistive Load max.
50W Inductive Load max.
: 230 Vac 50/60Hz 750 W max.
: 24 Vac 3 W max.
: -10 ÷ 55 °C
: see model
: Fix - Rolling Code - Plus
: 100(CODE + CODE PED)
: 105 x 95 x 64 mm.
: ABS V-0 (IP40).
Programming by SMARTPHONE :
The programming of the control panel can only be
performed via a Smartphone, thanks to the
dedicated SEAV "BeTech" application.
The application allows the installer to have a unique working
tool for all installations made.
Once the installation of the automation has been completed, on
request it will also be possible to configure an eventual
Customer Application for normal use via Smartphone to send
movement commands.
APP Features :
The SEAV "BeTech" application presents a phone book
containing all the data of the (central) plants produced.
It also allows you to set a Plant Name and a Password (Default:
1 2 3 4) to subsequently access the various configurations; the
possibility to restore a faulty power plant with a new one,
reloading all the information contained in the application's
address book. Furthermore, by entering an email address, it will
be possible to receive a Back Up of all the systems in case of
Smartphone failure. Possibility to install a new Firmware in the
control panel in case there is the need as well as access to a
Diagnostics for possible troubleshooting and much more.
Operating Mode :
Step by Step ( default ) :
the first command makes the opening until the engine time
expires or when the opening limit has been reached, the
second command closes the window; if a command is sent
before the engine time expires or if one of the two limit switches
is reached, the control unit stops the motion both during the
opening and closing phases. A further command determines
the resumption of motion in the opposite direction.
Inverting :
the first command makes the opening until the engine time
expires, the second command closes the window, if a command
is sent before the expiry of the engine time, the control unit
reverses the motion both in the opening phase and in the
closing one.
Inhibition Open Command :
the first command makes the opening until the engine time
expires, the second command closes the window, if a command
is sent during the opening or pause phase it ignores the
commands given (eg from the loop detector) at each crossing. If
a command is sent during the closing phase, the control unit
reverses the motion.
Dead Man :
the functioning of a Dead Man consists in having to always
keep the control button pressed to make the control unit open;
once the command is released, the control unit stops the
window.
A further command always maintained closes the window.
Dead Man during Closing Phase :
the functioning of Dead Man only in the closing phase, consists
in always having to keep pressed the control button to make the
control unit perform the closing; once the command is released,
the control unit stops the window, while in the Opening phase
the operation is impulsive (see Step by Step operation).