To ensure efficient operation and longer life of the air compressor outfit, a
routine maintenance schedule should be prepared and followed. The following
routine maintenance schedule is geared to an outfit in a normal working
environment operating on a daily basis. If necessary, the schedule should be
modified to suit the conditions under which your compressor is used. The
modifications will depend upon the hours of operation and the working
environment. Compressor outfits in an extremely dirty and/or hostile
environment will require a greater frequency of all maintenance checks.
Customer Responsibilities
Check Safety Valve
Drain Tank
Oil Leaks
Check Oil
Change Oil
Air Filter
1- more frequent in dusty or humid conditions
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When performing maintenance, you may be
exposed to voltage sources, compressed air, or moving parts. Personal
injuries can occur. Before performing any maintenance or repair,
disconnect power source from the compressor and bleed off all air
pressure.
NOTE: See "Operation" section for the location of controls.
To Check Safety Valve
Risk of Bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank
rupture or an explosion.
1.
Before starting compressor, pull the ring on the safety valve to make sure
that the safety valve operates freely. If the valve is stuck or does not
operate smoothly, it must be replaced with the same type of valve.
To Drain Tank
1.
Set the On/Auto/Off lever to "OFF" and unplug unit.
2.
zero when removing hose or accessories to prevent hose backlash.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing air to bleed from the tank until tank
pressure is approximately 20 psi. Release safety valve ring.
5.
Drain water from air tank by opening drain valve (counter-clockwise) on
bottom of tank. NOTE: Tilt tank to drain tank completely.
D29795
MAINTENANCE
Before
each
use
Risk of Flying Objects. Pull the regulator knob out and
turn counter-clockwise to set the outlet pressure to
16- ENG
Every
Every
Daily or
after each
8
40
use
hours
hours
Every
100
hours
1