TABLE 4. TROUBLESHOOTING CHART
system,­possible­defects­that­will­cause­there­symptoms­and­suggested­corrective­measure.­The­chart­assumes­that­the­proper­gas­
pressure­is­available­to­the­heater­and­that­the­lighting­procedure­is­as­stated­on­the­plate­attached­to­the­heater.
SYMPTONS
Burner­light­off­very­slow
Burner­light­off­very­slowly,­color­stays­dull
Burner­flashback­
(roaring­noise­during­operation­and­ceramic­
grid­surface­will­be­dark)
Ceramic grid or burner sooting up
(when­new­or­after­cleaning)
Pilot cannot be ignited
Pilot lights but goes out
Pilot stays lit but main burner will not light
Failure­to­ignite

HIGH ALTITUDE OPERATION

1.­ Installation­of­this­appliance­at­altitudes­above­2,000­ft­(610m)­shall­be­in­accordance­with­local­codes,­or­in­the­ab-
sence­of­local­codes,­the­National­Fuel­Gas­Code,­ANSI­Z223.1/NFPA­54­or­National­Standard­of­Canada,­Natural­Gas­
and­Propane­Installation­Code,­CSA­B149.1.
STOCK#
00277A
00278A
00279A
00280A
00283A
00284A
00281A
00282A
Enerco Group, Inc. | Gas-Fired Infra-Red Space Heaters
CAUSES
Partially blocked pilot orifice
Pilot out of adjustment
Partially blocked burner orifice
Low gas pressure
Damaged burner
First­check­for­damaged­burner­orifice
Checked for damaged manifold
Blocked­pilot­orifice
Gas­knob­not­in­correct­position
Pilot gas flow adjustment screw may be
closed
Defective­thermocouple
Defective­control
Loose wire or improperly wired
Defective­control
Blocked­burner­orifice
Main gas off
Air­in­gas­line
Loose wire connections
Dirty wire connections
HIGH INTENSITY OVERHEAD CONVERSION KITS
SP (Electric Spark)
DESCRIPTION SERIES
NG­to­LP­Kit
4040
LP­to­NG­Kit
4040
NG­to­LP­Kit
8060
LP­to­NG­Kit
8060
NG­to­LP­Kit
9100S
LP­to­NG­Kit
9100S
NG­to­LP­Kit
9120
LP­to­NG­Kit
9120
Below­in­chart­form­are­various­symptoms­of­a­malfunctioning­
SOLUTIONS
Re-adjust­pilot
Replace
Replace
Correct line pressure or call your gas
supplier
Replace
Replace if damaged
Replace
Replace
Gas­control­knob­must­be­turned­to­pilot­
and held depressed
Open­and­adjust­(see­figure­8)
Replace
Replace
Tighten­connections,­check­wiring­
diagram
Replace
Clean orifice or replace
Turn­on­main­gas
Bleed­gas­line
Tighten­wire­connections
Clean terminals and secure connections
PP (Power Pile)
STOCK#
DESCRIPTION SERIES
00285A
NG­to­LP­Kit
00286A
LP­to­NG­Kit
00287A
NG­to­LP­Kit
00288A
LP­to­NG­Kit
00291A
NG­to­LP­Kit
00292A
LP­to­NG­Kit
00289A
NG­to­LP­Kit
00290A
LP­to­NG­Kit
E7
Operating Instructions and Owner's Manual
4040
4040
8060
8060
9100S
9100S
9120
9120