Descargar Imprimir esta página

Important - Webasto SmarTemp Control 3.0 Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

SmarTemp Control 3.0
Mode changes the operation of the heater between heat mode and
ventilation mode. Status indicator lights will illuminate red for heat mode
Mode
and blue for ventilation mode (air heaters only) when the selected mode is
active.
User can select a specific day, time and heater runtime up to 7 days in the
future. Be aware this is a one-occurrence timer requiring the user to turn
the timer "ON" again after each scheduled timer use.
When selecting timer a sub-menu will appear (Edit, On, and Off). To modify
timer settings, select "edit". Select the day, time, and heater runtime using
Timer
the rotary knob and the selection button. Settings are saved each time the
selection button is pressed. If the timer function will be used regularly for
next day startups, the "ANY" setting can be used in place of the day of the
week. With this set, the timer will disregard the day setting and start during
the next 24-hour period based on the time selected. The "ANY" setting is
located in the list of days between Saturday and Sunday.
Duration allows for the selection of continuous heater operation or timed
operation. The heater runtime can be set to 30, 60, 90, or 120 minutes (air
heaters) or from 30 to 120 minutes, in 10-minute increments (coolant
heaters).
Duration
IMPORTANT: Timed duration is not to be mistaken for Timer functionality.
The duration times above are used when turning the heater on manually.
I.e. set the heater duration for 8 hours before heading to bed.
Note: If timed operation is selected 10 hours is default.
Language changes between English, Spanish, and French.
Language
This allows the user to set an offset (plus or minus 9ºF, 5ºC) to compensate
for any temperature difference between what the SmarTemp reads, and
Offset
what the operator feels.
NOTE: This function only applies to air heaters.
Temp Unit changes between Fahrenheit and Celsius units of measure.
Temp Unit
NOTE: This function only applies to air heaters.
LVD "Low Voltage Disconnect" allows the user to set the battery voltage
level at which the Webasto SmarTemp Control 3.0 will shut down the
heater. A warning (LED and message) will appear after 8 minutes of low
voltage. The warning will remain on for 2 minutes before the heater is
switched off.
LVD
If battery voltage is equal to or less than the threshold selected +0.1v, the
heater will not start. I.e. if an 11.5v threshold is selected the heater cannot
be started until B+ has reached 11.7v.
12 volt - Range between 11v – 12.5v
24 volt - Range between 21v – 25.5v
Definitions
7
Installation - Operating Instructions
Default
Value
Heat Mode
OFF
Continuous
English
Fahrenheit
11.4v
24.2v

Publicidad

loading

Este manual también es adecuado para:

Smartemp control 3.0 bluetooth