Wiring the IntelliFlo
To connect the IntelliFlo
1. Be sure all electrical breakers and switches are turned off before wiring motor.
2. Be sure that the wiring voltage is 230 VAC ± 10%.
3. Use 2.5 mm
4. Be sure all electrical connections are clean and tight.
5. Cut the wires to the appropriate length so they do not overlap or touch when connected.
6. Permanently ground the motor using the green ground wire, as shown below. Use the correct wire
size and type specified by local regulations.
7. Connect the wire from the accessible wire connector on the motor to all metal parts of the
swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal
piping within 5 feet of the inside walls of the swimming pool, spa, or hot tub.
8. The pump should be permanently connected to either a circuit breaker, 2-pole timer or 2-pole
relay.
9. IMPORTANT: When connecting the pump to an automation system (IntelliPool and
IntelliComm), continuous power must be supplied to the pump by connecting it directly
to the circuit breaker. When using an automation system, be sure that no other lights or
appliances are on the same circuit.
NOTE: When the IntelliFlo
device should be used to apply and remove power to both POWER LINE TERMINALS.
Ground Wire
Connection
IntelliFlo
Electrical Specifications
®
Circuit Protection: Two-pole 20 AMP safety device at the Electrical Panel.
Input: 230 VAC, 50/60 Hz, 3200 Watts, 1 phase
Pump
®
®
pump to an AC power source: