INSTALLATION MANUAL ADVANCE PLUS
ENGLISH
Warning:
If the pipe pressure is different to the fluid pressure, please contact the gas
company. For natural gas, the appliance must not be started at pressures
above 30 mbar. Close the gas inlet to the appliance.
Warning Service pressures exceeding 60 mbar are not allowed as some of the
oven's components could become unusable.
Ventilation
The appliances must be installed in such a way as to allow adequate ventilation
to prevent the unauthorised concentration in the premises of products emitted
during combustion which may be harmful to health.
We recommend the installation of a smoke and steam extraction hood in
accordance with the UNE–100165:92 standard. The hood should protrude from
the front of the appliance 200-400 mm.
We recommend the annual maintenance by an authorised technician of
the components relating to the gas installation.
TABLE OF CATEGORIES, GASES AND OPERATING PRESSURES
COUNTRY
AL - BG - DK - EE - FI - HR - LT -
LV - MK - NO - RO - SE
BE - FR
CH - CY - CZ - ES - GB - GR - IE -
IT - PT - SI - SK - TR
DE - LU
HU - IS - MT - NL
All manuals and user guides at all-guides.com
AT
PL
27
CATEGORY
PRESSURE
II
2H3B/P
II
2H3B/P
I
I
2H,
3+
II
20*28-30/37
2H3+
II
2E3B/P
II
2E3B/P
I
3B/P
20*50
20*30
20, 30
20*50
20*30
30