28 progress
The minimum distance between the
supporting surface for the cooking
equipment on the hob and the lowest part
of the range hood must be not less than
50cm from electric cookers and 65cm from
gas or mixed cookers. If the instructions for
installation for the gas hob specify a greater
distance, this must be adhered to.
Maintenance
ATTENTION! Before performing any
maintenance operation, isolate the
hood from the electrical supply by
switching off at the connector and
removing the connector fuse.
Or if the appliance has been connected
through a plug and socket, then the plug
must be removed from the socket.
The cooker hood should be cleaned
regularly (at least with the same frequency
with which you carry out maintenance
of the fat filters) internally and externally.
Clean using the cloth dampened with
neutral liquid detergent. Do not use
abrasive products. DO NOT USE
ALCOHOL!
Warning! Failure to carry out the basic
cleaning recommendations of the
cooker hood and replacement of the
filters may cause fire risks. Therefore,
we recommend observing these
instructions.
The manufacturer declines all responsibility
for any damage to the motor or any
fire damage linked to inappropriate
maintenance or failure to observe the above
safety recommendations.
Grease filter - The grease filter must
be cleaned once a month using non
aggressive detergents, either by hand
or in the dishwasher, which must be
set to a low temperature and a short
cycle. When washed in a dishwasher,
the grease filter may discolour slightly, but
this does not affect its filtering capacity.
All manuals and user guides at all-guides.com
Type 20 LONG LIFE - Washable
activated charcoal filter
The charcoal filter can be washed once
every two months using hot water and a
suitable detergent, or in a dishwasher at
65°C (if the dishwasher is used, select the
full cycle function and leave dishes out).
Eliminate excess water without damaging
the filter, then remove the mattress located
inside the plastic frame and put it in the
oven for 10 minutes at 100° C to dry
completely. Replace the mattress every 3
years and when the cloth is damaged.
Type 15 - NON-washable activated
charcoal filter
The saturation of the charcoal filter
occurs after more or less prolonged use,
depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the
cartridge at least every four mounths.
The charcoal filter may NOT be washed or
regenerated.
(1*)
(3**)
(**) Type 15 - Type 20
(*) Type 20
(2*)
(4**)