Preparation and transport guide,
Position
Position the dehumidifier where there is plenty of air circulation around it, with mini-
mum 60 cm of clearance on the air intake side, and 3 meters of clearance on the ex-
haust side. Remember also:
Location
Since the dehumidifiers contain a flammable refrigerant following location requirements
requirements
must be fulfilled:
Optimum operation Ensure the room to be dehumidified is sealed, and that the machine is not located near
a heat source, such as radiators.
Electrical connection The machine comes complete with a 3.5m power cord, and can be connected to any 230
V, 50 Hz socket with a 10-16A fuse.
If the plug has 3 pins incl. PE-connection a plug adapter (accessory – item no. 396249)
has to be used.
Warning: If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
To keep ventilation openings clear of obstruction during operation.
•
The appliance shall be installed, operated and
•
stored in a room with a floor area larger than
4m
. Check if there are any local regulations,
2
you must comply to, when installing or storing
the appliance.
The appliance shall be stored in a well-ventilated area, where the room size
•
corresponds to the room area of 4m
The appliance shall be stored in a room without continuously operating ignition
•
sources (for example: open flames, an operating gas appliance or an operating
electric heater.)
cont.
.
2