20/54
Function
Please note:
(1 cm³ 0.9 g lubricant)
Bosch Rexroth AG, MIT: LU 2, 3 842 358 814/2018-12
Table 6: Number of deliveries is dependent on the volume of the metered lubricant to be
delivered and the oil container LC L250
Delivery volume
[cm³/impulse]
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
6.2.1
Setting the delivery volume in the IMPULSE operating mode
The operating mode, the oil container used LC 2 ( LC250) and the required
delivery volume per impulse (delivery) are entered via the display using the SET
button.
The number of impulses (deliveries) can be taken from Table 6 on page 20.
Number of impulses (delivery) per oil
container LC 2 ( LC250)
2500
1250
833
625
500
417
357
313
278
250
208
179
156
139
125
114
104
96
89
83
71
62
56
50
45
42
38
36
33
31
29
28
26