Install Adapter Set As 2/C-100 - Bosch Rexroth LU 2 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 218
1.
Install the hose
connection (C) in the
lubricating pin (A).
2.
Insert the lubrication
pin (A) in the correct
position in the bore of
the drive head.
3.
Secure the lubrication
pin (A) with the lock
washer (B).
4.
Install the lubrication line.
Please note:
8.5.4

Install adapter Set AS 2/C-100, -250

B
Fig. 12:
Install adapter Set AS 2/C-100, -250
• Only use 2 equal lubricant pins (do not mix adapter sets).
Different lubricating pins cause unequal distribution through an uneven fl ow
resistance.
• The difference in length of the lubrication lines should be < 20 mm.
Different lubricating line lengths cause unequal lubrication distribution through an
uneven fl ow resistance.
• The lubrication line must always be placed lower than the lubricating pin,
otherwise the lubrication line runs empty (uncontrolled oil spillage, bubbles are
formed in the hoses)
• Fill the lubrication line before commissioning, e.g. by repeatedly pressing the
lubricating device (button in the PLC control) or using the special delivery PURGE
(see page 24), until lubrication comes out of the lubrication pin.
Assembly
A
C
3 842 358 814/2018-12, MIT: LU 2, Bosch Rexroth AG
33/54
358 814-04

Publicidad

Tabla de contenido
loading

Tabla de contenido