TROUBLESHOOTING

F A U L T
Water drips out
when moving unit
Unit does not
operate
Unit collects too
little water
If the problem you are experiencing is not listed here, contact your Legend Brands location for further
assistance.
SPECIFICATIONS
Model
Air filter
Weight
Dimensions
(H × D × W)
Power
Water removal AHAM
(80°F/60% RH)
Water removal max.
Water removal low grain
(80°F/20% RH)
Process air (max.)
Noise level (avg.)
Construction
Safety
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
07-02184B EB240
C A U S E
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Room air is dry.
Room temperature is too low.
Filter is full.
Heat exchange block and/or
coils are clogged.
EB240
EBF240
115 lbs. | 50 kg
33.5 × 20 × 20 in. | 85 × 51 × 51 cm
9.8 amps, 115V
145 pts. | 68.6 L / day
235 pts. | 111 L / day
17 pts. | 8 L / day
280 CFM* | 476 CMH*
65 dB
Rotomolded shell
Certified to CSA Std C22.2 No. 92
S O L U T I O N
Purge unit before moving. See "Before Moving Unit After
Use," p. 5.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Replace as necessary.
Check heat exchange block and coils. Clean as necessary.
PARTS INCLUDED
40 ft. (12 m) of drain hose with quick-connect fitting.
25 ft. (7.6 m) detachable power cord.
1 disposable air filter (reorder EBF240)
FOR PARTS AND SERVICE CALL YOUR LOCAL
DISTRIBUTOR or EnviroBoss at 800-932-3030.
www.EnviroBoss.com
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.