are already pre-assembled ready to plug in. No clamping work is required for
this. Only the 2-wire supply line of the light barrier transmitter at the inlet post
has to be connected to the 24 V AC power supply (terminals 17 + 18).
All input devices installed in the column:
- both key switches (pulse) - on both sides
- Emergency stop button - inside
are already pre-wired.
Of course, you can connect additional devices to the control system according to
your wishes. (However, only use BELFOX products. With third-party products,
errors can occur and destroy the motor control unit. If third-party products are
used, the warranty will become void). An extra terminal box at a comfortable
working height is provided for this purpose. The individual functions of the
connections can be found in the enclosed control instructions 47-21-0 (optional
control instructions 47-21-i).
Terminal diagram with control
47-21-0
1
Net L
2
Net N
3
Net PE
4
warning light 230 V AC
5
warning light 230 V AC
6
3-minute light 230 V
7
3-minute light 230 V
8
Switch impulse
9
Switch common
10
Switch partial opening
11
Switch partial opening
12
Switch partial opening
13
Stop
14
Stop
15
Main closing edge
16
Main closing edge
17
secondary closing edge
18
secondary closing edge
19
24 V AC max. 0,5 A
20
24 V AC max. 0,5 A
Terminal diagram with control
47-21-i
1
Netz L
2
Netz N
3
Trafo N – 230 V
4
Trafo L – 230 V
5
3-Minutenlicht N - 230 V
6
3-Minutenlic ht L - 230 V
7
Warnlicht N – 230 V
8
Warnlicht L – 230 V
9
Trafo 24 V
10
Trafo 24 V
11
24 V Abgriff – Klemme 10
12
24 V Abgriff – Klemme 9
13
24 V DC - Masse
14
24 V DC - +24 Volt
21
Taster A - Impuls
22
Gemeinsamer A & B
23
Taster B - Auf
24
Taster C – Zu
25
Gemeinsamer C & D
26
Taster D – Teilöffnung
27
Stopp
28
Stopp
29
Lichtschranke
30
Lichtschranke
31
/
32
SE1 (8,2 k )
33
SE2 (8,2 k )
34
/
35
SE1 (8,2 k )
36
SE2 (8,2 k )
28
Ω
Ω
Ω
Ω