1 - INTRODUCTION
•
All the parts subject to wear (belts, filters, blades, seals, etc.) are not subject to the warranty
•
The eventual costs of intervention performed by the Campagnola personnel (inspections, disassembling and assembling
operations), caused by wrong working which was not due to manufacture faults, are not included in the warranty.
•
Replacements or repairs of faulty equipment, when warranty is claimed by the users, can only be authorized by accredited
Service Points personnel and their decision is final.
•
The Company shall not be held responsible for any injury or damage caused to people, animals or things, due to improper
use or maintenance of the compressor and/or tools. The warranty is limited to the manufacture defects.
•
The warranty is lost in case of tampering and /or even small changes and in case of use of non-original spare parts.
•
In any case the replacement of the tool is excluded.
WARNING!
For warranty claims, according to the above mentioned points, it is necessary to enclose the properly filled-in warranty
card and the corresponding purchase proof with date of purchase (invoice or any other document with legal value).
2
- SAFETY PRECAUTIONS
2.1 Precautions
WARNING!
The manufacturer declines all responsibilities if the precautions below are not taken.
2.1.1 Results of the tests made by law
WARNING!
Risks due to the operator's contact with the noise and vibrations of the machine or tool.
1)
NOISE LEVEL
Continuous sound pressure level A in the working place, measured according to the UNI EN ISO 3744 regulations:
The levels measured at the various auxiliary equipment are high as they exceed the set reference limit
LpA
= 70 dBA.
eq
The following obligations have to be fulfilled:
•
The operator shall undergo a periodic check up.
•
The operator must be informed of the risks faced caused by exposure to high noise levels.
•
Safe and adequate sound barriers or other hearing protection must be used.
2)
VIBRATIONS LEVEL
Average weighted hand-transmitted vibration value, in frequency, the user is exposed to measured in compliance
with EN ISO 5349/1-2:
Direct shear
Shear with 0.5 m fixed length extension pole
Shear with 1.0 m fixed length extension pole
Shear with 1.5 m fixed length extension pole
Shear with 2.0 m fixed length extension pole
Shear with 2.5 m fixed length extension pole
Shear with 3.0 m fixed length extension pole
Shear with 0.70 ÷ 1.10 m telescopic extension pole in fibreglass
Shear with 1.25 ÷ 1.95 m telescopic extension pole in fibreglass
Shear with 1.85 ÷ 3.15 m telescopic extension pole in fibreglass
LpA
= 87 dBA
eq
a
a
a
a
a
a
a
a
a
a
= 4.59 m/s
2
heq
= 3.30 m/s
2
heq
2
= 5.74 m/s
heq
= 5.38 m/s
2
heq
= 5.74 m/s
2
heq
2
= 3.87 m/s
heq
2
= 4.05 m/s
heq
= 6.46 m/s
2
heq
2
= 5.47 m/s
heq
2
= 4.52 m/s
heq
15 - 64