WET OR GEL BATTERY SETTING
NOTE
With electronic battery charger, this must be connected to the batteries to allow the machine to operate.
According to the type of batteries (WET or GEL), set the electronic board of the machine and the battery charger, according to the
following procedure:
1.
Turn the ignition key (72) to "0".
2.
Open the hood (7).
Machine setting
1.
The machine factory setting is for lead (WET) batteries. If this setting corresponds to the type of batteries installed on the
machine, go to the next paragraph, otherwise perform the following procedures:
•
Disconnect the battery connector (46).
•
Remove the screws (83) and carefully remove the right control panel (84).
•
Install a jumper wire (A, Fig. 1) on "GEL" connectors (B) for gel batteries.
•
Carefully install the control panel (84) and the relevant screws.
•
Connect the battery connector (46).
Battery charger setting
1.
Turn the battery selector (49) to WET for lead batteries or to GEL for gel batteries.
2.
Charge the batteries (see the procedure in Maintenance chapter).
BEFORE MACHINE START-UP
CAUTION!
Make sure that there are no open doors/hoods and that the machine is in normal operating conditions.
Make sure that the hopper (17) is properly closed.
If the machine has not been used after being transported, check that all the blocks used for the transportation
have been removed.
INSTRUCTION FOR USE
C
Figura 1
1464035000(1)2009-06
Terra™ 4300B
B
A
ENGLISH
S311412
13