APPENDIX A: USING ELCOMASTER (continued)
Stop triggers are handled in a similar way:
Run Duration: will stop logging after a pre-defined set time.
Threshold Temperature: will stop logging when the temperature of
the probe connected to channel 1 falls below the set temperature.
If nothing is selected, the logging will stop when either the
maximum run time is reached or logging is stopped manually.
Once the settings file has been created, click 'Upload' to upload the
data directly to the logger and follow the on-screen instructions.
A.3 CREATING A NEW PAINT TYPE
Time and temperature data for the paint type can be added to allow
the logger to perform a cure calculation providing the user with a
numerical value for how well the coating has cured at each probe
location.
A cure calculation of 100 represents a coating which has only just
cured with less representing a coating which has not cured enough. A
cure calculation greater than 100 is not usually an issue as long as the
maximum temperature is not exceeded. If significantly greater than
100 however, there may be scope for increasing efficiency by speeding
up the process or turning the oven temperature down.
The cure calculation result is shown both on the logger screen and
also within ElcoMaster at the end of the run.
To create a new paint type:
1
Click on the 'Oven Profiling' tab.
2
Click 'New''Paint Type'. A new
file is created labelled 'New Paint
x'. To rename file, right-click and
select 'Rename'.
Various tabs are now available for data
entry.
Description: add basic data regarding the paint type and upload
the manufacturers' data sheet (pdf format) if available.
en-15