Descargar Imprimir esta página

Publicidad

Enlaces rápidos

Electrical Control Cabinets
I
ntroduction
Designed to facilitate installers work, this range
of electrical cabinet is intended for use in cold
rooms working at positive or negative
temperatures and powered either with single
phase or three phase power supply.
Based on specifically designed controllers, it
incorporates all control functions as required by
modern cold room units, such as compressor
control, defrost management, fan management,
alarm function and solenoid valve for "pump
down".
It also includes all the safety equipment needed
such as circuit breakers for the compressor and
for the controller.
Particular attention has been given to the
accessibility so that the installation time will be
reduced to a minimum. Space has been left
available for customisation.
!
Power rating from :
0,37 to 1,5 kW in single phase
1,5 to 7,5 kW in three phases
!
Standard DIN rail components
!
Most wiring integrated on the controller
!
Specifically designed controller to
manage Pump Down
!
Accurate and interchangeable
IP 68 sensor
!
IP 65 standard DIN polycarbonate cabinets
!
Integrate circuit breaker for motor and
controller
!
In field extension
!
Main Switch
© 2000 Johnson Controls, Inc.
Order No. P-CR-E
All manuals and user guides at all-guides.com
Including digital controller
Features and Benefits
Refrigeration Controls Catalogue
Catalogue Section
Product Bulletin
12 modules (front) and 36 modules (back)
models
Cover most of standard applications.
Easy maintenance and servicing.
Availability of components.
Increased quality and reduced space occupancy.
Better match application need.
Accurate control performance.
No re-calibration needed.
High mechanical resistance.
Installation in harsh environment.
No time lost defining appropriate protection
Possibility to field connect a condensing fan or a
door frame heater.
To power down the whole cabinet.
Increased safety protection.
9
CR1
Issue
0101
Catalogue Section 9

Publicidad

loading

Resumen de contenidos para Johnson Controls MR12DR230-1C

  • Página 1 No time lost defining appropriate protection controller In field extension Possibility to field connect a condensing fan or a door frame heater. Main Switch To power down the whole cabinet. Increased safety protection. © 2000 Johnson Controls, Inc. Catalogue Section 9 Order No. P-CR-E...
  • Página 2 Sensor The high protection level (IP65) allows you to install this cabinet in harsh environment such as The CR series uses Johnson Controls A99 outdoors. The polycarbonate material has a high temperature sensor. Its accuracy, ± 0.5 K over a range from -20ºC to 75ºC, and its gas tight...
  • Página 3 • you do not touch or attempt to connect or wire a separate backup control (e.g. a freeze protection thermostat) in order not to use the disconnect wires when electric power is on. controller as an operating and safety device. © 2010 Johnson Controls, Inc. Catalogue Section 9...
  • Página 4 Amps Amps modules 0,37 kW CR-PS037-1 0,75 kW CR-PS075-1 1,1 kW CR-PS110-1 1,5 kW CR-PS150-1 1,5 kW CR-PT150-1 2,5 kW CR-PT250-1 4,0 kW CR-PT400-1 5,5 kW 11,5 CR-PT550-1 7,5 kW 15,5 CR-PT750-1 Catalogue Section 9 © 2000 Johnson Controls, Inc.
  • Página 5: Wiring Diagram

    8 T4 A larm Cond. Fan / 230V~ Door fram e 0,5 A Valv e Pum p C ompressor down 230 Volts 3 ~ 400 Volts Positive temperature cold room three phase model © 2010 Johnson Controls, Inc. Catalogue Section 9...
  • Página 6 Amps Amps modules CR-NS037-1 0,37 kW CR-NS075-1 0,75 kW CR-NS110-1 1,1 kW CR-NS150-1 1,5 kW CR-NT150-1 1,5 kW CR-NT250-1 2,5 kW CR-NT400-1 4,0 kW CR-NT550-1 5,5 kW 11,5 CR-NT750-1 7,5 kW 15,5 Catalogue Section 9 © 2000 Johnson Controls, Inc.
  • Página 7 Va lv e Pu m p Compressor Fa n do w n 23 0 Volts 3 ~ 4 00 Volts D efros t 23 0 V ~ Negative temperature cold room three phase models © 2010 Johnson Controls, Inc. Catalogue Section 9...
  • Página 8 Door fram e Valv e Pum p Compressor do w n 230 Volts 3 ~ 400 Volts D efrost 230 V 3~ Negative temperature cold room three phase Compressor and three phase Defrost models Catalogue Section 9 © 2000 Johnson Controls, Inc.
  • Página 9 D efrost 230 V 3~ F a n 3 ~ 40 0 Vo lts WIRING DIAGRAM FOR: CR-NFDT150-1 / CR-NFDT400-1 / CR-NFDT750-1 Negative temperature cold room- three phase Compressor, Defrost and Evaporator Fan © 2010 Johnson Controls, Inc. Catalogue Section 9...
  • Página 10 If your set point is at 4ºC and you want an alarm After defrost is terminated, the compressor is 3 K below setpoint, it will be triggered at 1ºC. stopped to allow the evaporator to drip. Catalogue Section 9 © 2000 Johnson Controls, Inc.
  • Página 11 Fan start-up delay after defrost end: This parameter is a safety function, the fan is activated after this time even if the temperature set through parameter Fr has not been reached © 2010 Johnson Controls, Inc. Catalogue Section 9...
  • Página 12 2 = Automatic • • Offset thermostat sensor -20 to +20 units • • Temperature units 0 = °C 1 = °F • • Display updating time delay 1 to 99 sec Catalogue Section 9 © 2000 Johnson Controls, Inc.
  • Página 13 For further details refer to manufacturer’s documentation (in this case ABB). Defrost and controller in the NFDT models are fuse protected. For further details refer to manufacturer’s documentation (in this case ABB) © 2010 Johnson Controls, Inc. Catalogue Section 9...
  • Página 14 Temperature sensor, 2 mts cable, IP68, stainless steel Johnson Controls Note: In case of defective or improperly functioning control, please check with your nearest Johnson Controls / Penn supplier. When contacting the supplier for replacement, you should state the type or model number of the control.
  • Página 15 All manuals and user guides at all-guides.com otes © 2010 Johnson Controls, Inc. Catalogue Section 9...
  • Página 16 The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. This document is subject to change without prior notice.
  • Página 17 All manuals and user guides at all-guides.com P/n 24-85737-84 Rev.B READ THIS INSTRUCTION SHEET CAREFULLY BEFORE INSTALLING AND LISEZ CETTE FEUILLE D'INSTRUCTION ATTENTIVEMENT AVANT SAVE FOR FUTURE USE L'INSTALLATION ET METTEZ-LA DE CÔTÉ POUR UN USAGE FUTUR The electrical cabinet CR is a low voltage switchgear and controlgear assembly L’armoire électrique CR est un assemblage de commutation et de com- complying with EN 60439-1 (TTA).They are suitable for wall mount, and outdoor mande à...
  • Página 18 22 si no se utiliza un interruptor de presión. malen Schutz gegen Über- oder Unterdruck sind Druckschalter aus dem Hause JOHNSON CONTROLS der Baureihe P77 oder P78 zu wählen und entsprechend zu verdrahten. Sollte die Kälteanlage gemäß UVV20(VGB20) eigensicher sein, so ist die beiliegende Kabelbrücke zu verwenden.
  • Página 19 All manuals and user guides at all-guides.com P/n 24-85737-84 Rev.B VAR GOD LÄS INSTRUKTIONERNA NOGGRANT FÖRE LÆS DENNE VEJLEDNING OMHYGGELIGT FØR INSTALLATIONEN, OG LUE NÄMÄ OHJEET HUOLELLISESTI ENNEN LAITTEEN ASENNUSTA JA INSTALLATIONEN OCH BEVARA DEM FÖR FRAMTIDA BRUK OPBEVAR DEN TIL SENERE BRUG SÄILYTÄ...
  • Página 20 All manuals and user guides at all-guides.com P/n 24-85737-84 Rev.B...