- GB -
Solo operation
C
• Only install the unit in the permitted positions to ensure fault-free operation.
• Take the required distances into consideration. (→ Distances to be adhered to)
• Use suitable fastening material for the type of ground. Ensure that the fastening means securely hold the unit. Take
the weight of the unit into consideration. (→ Technical data)
• Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be installed below the water level.
This allows the water supply to be shut off for maintenance work.
Connecting the inlet
Use hoses that are suitable for a pressure of at least 1 bar.
How to proceed:
8.
0.
D
1. Push the inlet nozzle into the inlet.
− The inlet nozzle is only necessary for a flow rate < 10000 l/h to ensure unimpaired rotation of the cleaning rotor.
2. Screw the hose connector with union nut and seal onto the inlet.
3. Connect the hose with the stepped hose adapter and secure with a hose clip.
Connecting the outlet
How to proceed:
4.
0.
E
1. Screw the stepped hose adapter with union nut and seal onto the adapter.
2. Connect the hose with the stepped hose adapter and secure with a hose clip.
3. Screw the cover cap with flat seal onto the outlet.
− The cover cap has to close the outlet opposite the inlet so that the main flow of water is guided along the UVC
lamps and is exposed to the UV radiation for as long as possible.
Connect the unit to the flow-through filter.
• Take the required distances into consideration. (→ Distances to be adhered to)
• Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be installed below the water level.
This allows the water supply to be shut off for maintenance work.
ProfiClear Premium / ProfiClear Classic / BioSmart
This section describes the connection of the UVC clarifying unit Bitron with a pump fed system.
• Please adhere to the instructions for use of the flow-through filter.
4.
How to proceed:
0.
F, G
1. Insert the outlets with flat seals through the holes in the container wall.
2. Fitting the inlet:
− ProfiClear Premium: First screw the adapters onto the outlets and hand tighten. Then screw the 30° inlet bends
with the union nuts onto the adapters and hand tighten. Ensure that the openings point downward.
− ProfiClear Classic / BioSmart: Screw the inlet nozzles with the O rings onto the outlets and hand tighten.
3. Closing the bypass (optional):
− ProfiClear Premium: Screw the cover cap onto the outlet instead of the adapter and inlet bend.
− ProfiClear Classic / BioSmart: Screw the cover cap onto the outlet instead of the inlet nozzle.
4. Connect the Bitron to the filter pump. (→ Connecting the inlet)
BioTec ScreenMatic
• Please adhere to the instructions for use of the flow-through filter.
5.
How to proceed:
0.
H
1. Insert the outlets with flat seals through the holes in the container wall into the distributor.
2. Screw the distributor nuts with O rings onto the outlets and hand tighten.
3. Connect the Bitron to the filter pump. (→ Connecting the inlet)