5.1.4 "Energy Manager"
Operating mode "Energy Manager"
Start of charg-
Without RFID card:
ing process
„ Automatically after connection to the vehicle
With RFID card:
„ Authentication with valid RFID card
„ Manually via the MENNEKES Charge APP by selecting a valid RFID card.
Controlling the
About the Energy Manager:
charging pro-
„ The Energy Manager specifies the charging current according to the parameters set in the
cess
MENNEKES Charge APP.
Via the MENNEKES Charge APP:
„ Terminating the charging process.
„ Changing the remaining amount of charging energy.
„ Changing the remaining charging time.
„ Changing the distribution of solar energy (enable / disable excess charging).
By using the multifunction button:
„ Terminating the charging process.
The stop function with the multifunction button must be enabled during the setting-up process.
With RFID card:
„ Terminating the charging process with the same card used for starting the charging process.
Setting up the
To use the operating mode "Energy Manager", it is necessary to install the respective devices (such
operating mode
as a photovoltaic system) in the household application and to implement the Energy Manager.
f If necessary, it has to be installed by a qualified electrician.
Changing the
By using the MENNEKES Charge APP during a charging process:
operating mode
„ Change to operating mode "APP control".
The change of operating mode will apply to the on-going charging process. The following charging
process is performed in the mode selected in "Configure Wallbox".
Via the MENNEKES Charge APP in "Configure Wallbox":
„ Changing to all operating modes configured during the setting-up process.
The change of operating mode will apply for the on-going and subsequent charging processes.
Behaviour after
The behaviour after a power failure is configured during setting-up process.
a power failure
„ The charging process is aborted (default with RFID card reader).
„ The charging process is continued (default without RFID card reader).
16
In operating mode "Energy Manager", the functions of the operating modes "Time control"
and "Mains control" are disabled. The charging capacity is then not controlled by time or
the network.