Descargar Imprimir esta página
RISCO Group BWare RK515DTG3 Manual De Instrucciones
RISCO Group BWare RK515DTG3 Manual De Instrucciones

RISCO Group BWare RK515DTG3 Manual De Instrucciones

Publicidad

Enlaces rápidos

K-Band DT AM
Grade 3 Detector
Model: RK515DTG3
EN G LI S H
The BWare DT AM detector is the ultimate motion detector for professional
installations, incorporating both Anti-Mask and Anti-Cloak™ Technologies
(ACT™) and includes built-in end-of-line (EOL) resistors to simplify installation.
The detector employs K-Band microwave providing reduced wall penetration.
Installation / Maintenance
Mounting - The BWare DT AM can be mounted either on a flat surface or on a
wall corner (corner mounting).
1. Remove detector's front cover using a suitable tool (as described in
Figure 1).
2. Using a suitable tool, open the following knockouts on the detector's
base (see Figure 2).
Note:
If a back tamper is to be used it is mandatory to screw the tamper back
plate to the wall (or wall corner).
3. To select the correct vertical adjustment position for wide angle lens,
use the scale on the bottom right hand side of the PCB cover as follows:
Mounting height and scale position based on room size:
Mounting Height
L - LONG
S - SHORT
2.1m-2.7m (6'11"-8'10")
15m (50')
6m (20')
4. Set jumpers (see Jumper Setting section).
Note:
Reset the detector after each change made to the settings.
5. Install the front cover back to its place (in a reverse sequence of the removal).
6. Perform a Walk test (see Walk Test section below).
Terminal Wiring (see Figure 5)
Terminal
Description
- 12 +
12VDC Input
ALARM
N.C. Relay
TAMPER
N.C. Tamper switch
FAULT/AM
Normally Closed Relay: The FAULT/AM relay opens in the following
events:
• Detector is masked (Alarm relay is also opened)
• Self test failed
• Input voltage is lower than 8VDC
LED
LED operation remote control
When an "Activation Signal"** is applied to the LED input terminal, all
LEDs will be disabled.
LEDs are enabled if nothing is connected (unless LED jumper is OFF) or
0V/12V is applied (according to the LED/SET Input Jumper position,
12V or 0V).
SET
Remote SET/UNSET control
SET: If an "Activation Signal"** is applied, anti-mask detection is disabled
(for Grade 2 configuration).
UNSET: If nothing is connected or 0V/12V is applied (according to the
LED/SET Input Jumper position, 12V or 0V) anti-mask detection is
enabled (see also "Green Line" and "Remote Self Test"
**Activation Signal-
If 12VDC is applied, and the LED/SET Input Jumper is on 12V position
(Default position)
- Or -
0V is applied and LED/SET Input Jumper is on 0V position
Jumper Settings
Jumper
Function
SW1-1: LED
Used to determine the operation of the detector's LEDs
ON:
LEDs are enabled, allowing LED control via the LED input terminal
(Default)
OFF:
LEDs are disabled
SW1-2: ACT
Used to determine if ACT mode is enabled or disabled
ACT Enabled
ON
Important:
Do not use ACT™ mode if you are expecting that there will
be moving objects outside the required protected area, a corridor for
example.
OFF
ACT Disabled.
(Default)
SW1-3: Green Line
The BWare DT AM includes a Green Line feature that follows environmental guidelines.
This feature disables the MW channel when the alarm system is "Unset", thus
eliminating surplus MW emission while the premises is occupied.
Green Line feature is enabled: To deactivate the MW module during
ON
"UNSET", the LEDs must also be remotely disabled by the LED terminal.
Note:
When 'Green Line' is on (Microwave off), the detector will still
activate (PIR only)
OFF
Green Line feature in disabled: MW is constantly in use.
(Default)
SW1-4: Self
Used to test detection technologies.
Test
(Local Self Test): If there is no alarm detection in the PIR channel for
ON
a period of one 1 hour, the detector will self-test. If the local self test
fails, the FAULT/AM Relay will activate.
(Remote Self Test): Remote Self Test is activated when the SET
OFF
terminal is switched from SET to UNSET mode. For remote self test
(Default)
ass, the Alarm Relay will activate for 5 seconds.
J1 - Alarm EOL
Jumpers J1 and J2 allow the selection of Tamper and Alarm
J2 - Tamper EOL
resistance (1K, 2.2K, 4.7K, 5.6K, 6.8K) according to the control
J3 - FAULT/AM
panel (see Figure 4) Jumper J3 allows the selection of 12K for
EOL
Fault/Anti-Mask.
Follow the terminal block connection diagram in Figure 4 when
connecting the detector to a Double/Triple End Of Line
(DEOL/TEOL) Zone.
J4 - LED/SET
Used to determine the polarity of the external input.
INPUT
See Terminal Wiring section, LED and SET Terminals
(Default)
See Terminal Wiring section, LED and SET Terminals
Walk Test
Important:
The detector cover must be closed when applying power or
within 30 seconds after applying power, otherwise AM calibration will fail.
1. Two minutes after applying power (warm-up period), walk test the Detector over
the entire protected area to verify proper operation of the unit (see Figure 7).
2. The K-Band MW range must be adjusted using the potentiometer located on
the PCB. It is important to set the potentiometer to the lowest possible setting
that will still provide enough coverage for the inner boundary protected area
(see Figure 5).
U.S. Patent Number:
This product is protected under Patent No. US 7,126,476 B2.
Other patents pending.
CE Compliance Section:
Risco Ltd. hereby declares that this equipment is in compliance with the
essential requirement and other relevant provisions of Directive 1999/5/EC.
For the EC Declaration of Conformity please refer to our website:
www.riscogroup.com
EN 50131-1
EN 50131-2-4
Grade 3
Environmental Class II
Contains FCC ID UXS-IPM165F
BWare RK515DTG3 FCC Compliance Section:
FCC Part 15 Note:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician.
FCC Warning:
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the
user's authority to operate the equipment.
LEDs Display
LED
State
Description
Yellow
On
PIR detection
Flashing
Trouble in PIR channel
Green
On
MW detection
Flashing
Trouble in MW channel
Blue
On
ALARM
Flashing
Fault / Anti-Masking detection
Note:
Anti Masking detection is operational in "Unset" mode
only (see Terminal Wiring section, SET terminal).
At power-up, the LEDs will flash consecutively until the end
All LEDs Flashing
consecutively
of the warm-up period (2-3 minutes). At the end of the
warm-up period the RED LED will continue to flash until the
end of AM calibration.
Note:
AM and Trouble indications continue until masking is removed or trouble
is corrected.
Technical Specification
Electrical
Current consumption
16mA at 12VDC (typical)
41mA at 12VDC (max.)
Voltage requirements
9 -16VDC***
Alarm contacts
24VDC, 0.1A
Tamper contacts
24VDC, 0.1A
FAULT/AM contacts
24VDC, 0.1A
Environmental
RF immunity
According to EN50130-4
Operating temperature
-10ºC to 55ºC (14ºF to 131ºF)
Storage temperature
-20ºC to 60ºC (-4ºF to 140ºF)
Optical
Filtering
White Light Protection
Physical
Size
127.6 x 64.2 x 46.6 mm (5 x 2.5 x 1.84 in.)
Weight
120 gr. (4.2 oz.)
*** Power to be supplied by 5A max. power source using safety approved
wires, with a min Gauge of 20AWG.
ITALIANO
Il rivelatore BWare DT AM è un rivelatore di movimento che integra le tecnologie
più avanzate per le installazioni professionali. Questo rivelatore include sia la
tecnologia Anti-Mask che quella Anti-Cloak™ (ACT™) ed ha le resistenze di fine
linea integrate nel circuito per semplificarne al massino l'installazione.
Il rivelatore BWare DT AM utilizza la microonda in banda K la quale consente
una penetrazione ridotta attraverso i muri.
Installazione / Manutenzione
Installazione - Il rivelatore BWare DT AM può essere installato sia su di una
superficie piana che ad angolo.
1. Rimuovere il coperchio del rivelatore utilizzando un attrezzo appropriato
(come descritto nella Figura 1).
2. Utilizzando uno strumento appropriato aprire i fori a sfondare, di seguito elencati,
della base del contenitore come illustrato in Figura 2.
Nota:
Se deve essere utilizzato il tamper antirimozione è obbligatorio avvitare al
muro (o angolarmente al muro) la linguetta del tamper antirimozione.
3. Per selezionare la posizione corretta della scheda elettronica con la lente
grandangolo montata, usare i riferimenti ( LONG / SHORT) situati nella parte
inferiore destra della scheda elettronica seguendo le indicazioni della tabella di
seguito illustrata:
Altezza di installazione e regolazione scheda elettronica in funzione
dell'areadi copertura:
Altezza di installazione
L - LONG
S - SHORT
2.1m-2.7m
15m
6m
4. Predisporre i ponticelli e i microinterruttori (Vedere la sezione relativa).
Nota:
Ad ogni modifica delle predisposizioni/regolazioni, effettuare sempre un
reset del rivelatore rimuovendo e applicando tensione.
5. Rimontare il coperchio frontale e stringere la vite di blocco coperchio.
6. Effettuare una prova di copertura (Sezione Prova di movimento vedere in basso).
Cablaggio Morsettiera (vedere Figura 5)
Morsetto
Descrizione
- 12 +
Ingresso di alimentazione 12V
ALARM
Relé N.C.
TAMPER
Interruttore N.C.
Relé N.C.: Il relé FAULT/AM si attiva per gli eventi seguenti:
FAULT/AM
Il rivelatore è mascherato (anche il relé di allarme viene attivato)
L'auto-test del sensore è fallito
L'ingresso di alimentazione è minore di 8V
LED
Controllo remoto dei LED e funzione GREEN LINE (con
microinterruttore SW1-3 in posizione ON)
Quando viene applicato un "Segnale di Attivazione"** al morsetto LED,
tutti i LED vengono disabilitati e, se il microinterruttore GREEN LINE è in
ON, la sezione microonda viene disabilitata.
Nota:
affinché la microonda venga disabilitata non ci deve essere alcun
comando sul morsetto SET.
I LED sono abilitati se al morsetto LED non è collegato niente (a meno che
il ponticello LED sia estratto).
.
SET
Controllo remoto dello stato impianto
Stato Inserito: Quando viene applicato un "Segnale di Attivazione"** a
questo morsetto, il circuito di Anti-Mask viene disabilitato
Stato Disinserito: Se all'ingresso non viene collegato niente il circuito
Anti-Mask è abilitato (vedere anche la tabella di predisposizione ponticelli
e microinterruttori riferita alla funzione "Green Line" e "Auto-test
Sensore".
**Per Segnale di attivazione si intende quanto segue-
- Viene applicata una tensione 12 Vcc e il ponticello LED/SET Input è nella
posizione 12V (posizione di default)
- Viene applicato un riferimento di alimentazione 0V e il ponticello LED/SET Input
è nella posizione 0V
Predisposizione microinterruttori e ponticelli
Microint./Pontic.
Funzione
SW1-1: LED
Usato per abilitare o disabilitare il funzionamento dei LED.
ON
I LED sono abilitati ed è possibile anche controllarli via comando
(Default)
remoto tramite l'ingresso LED.
OFF
I LED sono disabilitati. Non è possibile alcun controllo remoto.
SW1-2: ACT
Usato per abilitare o disabilitare la funzione ACT
ON
ACT abilitato
OFF
ACT disabilitato.
(Default)
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products
to be free from defects in materials and workmanship under normal use for 24
months from the date of production. Because Seller does not install or connect
the product and because the product may be used in conjunction with
products not manufactured by the Seller, Seller cannot guarantee the
performance of the security system which uses this product. Seller's obligation
and liability under this warranty is expressly limited to repairing and replacing,
at Seller's option, within a reasonable time after the date of delivery, any
product not meeting the specifications. Seller makes no other warranty,
expressed or implied, and makes no warranty of merchantability or of fitness
for any particular purpose.
In no case shall seller be liable for any consequential or incidental damages
for breach of this or any other warranty, expressed or implied, or upon any
other basis of liability whatsoever.
Seller's obligation under this warranty shall not include any transportation
charges or costs of installation or any liability for direct, indirect, or consequen-
tial damages or delay.
Seller does not represent that its product may not be compromised or
circumvented; that the product will prevent any personal injury or property loss
by burglary, robbery, fire or otherwise; or that the product will in all cases
provide adequate warning or protection.
Seller, in no event shall be liable for any direct or indirect damages or any
other losses occurred due to any type of tampering, whether intentional or
unintentional such as masking, painting or spraying on the lenses, mirrors or
any other part of the detector.
Buyer understands that a properly installed and maintained alarm may only
reduce the risk of burglary, robbery or fire without warning, but is not insurance
or a guaranty that such event will not occur or that there will be no personal
injury or property loss as a result thereof.
Consequently seller shall have no liability for any personal injury, property
damage or loss based on a claim that the product fails to give warning.
However, if seller is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause
or origin, seller's maximum liability shall not exceed the purchase price of the
product, which shall be complete and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this warranty
in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.
CAUTION: risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to local regulations.
© RISCO Group 09/2011
Microint./Pontic.
Funzione
SW1-3: Green Line
BWare DT AM include la funzione Green Line che evita emissioni radio superflue
nell'ambiente. Questa funzione disabilita il canale a microonda (MW) quando il sistema
di sicurezza è disinserito.
La funzione Green Line è abilitata: Per disabilitare la sezione
microonda (MW) a sistema DISINSERITO va applicato un comando
di attivazione al morsetto LED (0V o 12V in funzione della polarità
ON
configurata tramite il ponticello LED/SET INPUT). Anche i LED
verranno in questo caso disabilitati. La sezione microonda viene
disabilitata in questo modo solo se al morsetto SET non viene
applicata alcuna tensione.
Nota:
Quando la funzione Green Line è attiva (Microonda spenta), il
rivelatore si attiva usando la sola sezione ad infrarossi (PIR).
OFF
La funzione Green Line è disabilitata. La sezione a microonda (MW) è
(Default)
sempre accesa.
SW1-4: Self
Usato per testare le tecnologie di rilevazione.
Test
(Auto-test locale): Se non viene rilevata alcuna attivazione del canale
ON
PIR per 1 ora, il rivelatore eseguirà un auto-test. Se il test fallisce,
l'uscita a relé FAULT/AM verrà attivata.
(Auto-test remoto): L'Auto-test remoto si attiva quando il morsetto
SET viene portato dalla condizione di Impianto INSERITO (Comando
OFF
di attivazione applicato) alla condizione di impianto DISINSERITO
(Default)
(nessuna tensione applicata). A conferma che l'auto-test remoto è
stato superato l'uscita a relé di allarme si attiverà per 5 secondi.
Nel caso in cui l'auto-test sia fallito si attiverà l'uscita a relé FAULT/AM.
I ponticelli J1 e J2 permettono la selezione dei valori resistivi da
J1 - Alarm EOL
assegnare ai circuiti di Tamper e di Allarme (1K, 2.2K, 4.7K, 5.6K,
J2 - Tamper EOL
6.8K) in funzione della centrale d'allarme utilizzata (vedere la
J3 - FAULT/AM EOL
Figura 4 in basso). Il ponticello J3 inoltre, permette la selezione
Ponticelli Per
di una resistenza di 12K per supervisionare il circuito
resistenze EOL
Anomalia/Anti-Mask.
Seguire lo schema di collegamento dei morsetti illustrato in
Figura 4 quando si vuole collegare il sensore ad una centrale
d'allarme usando il doppio o il triplo bilanciamento resistivo
(DEOL/TEOL).
J4- LED/SET
Usato per impostare la polarità dei comandi di attivazione per
INPUT
gli ingressi LED e SET.
Posizionato sul lato 12V richiede come comando di attivazione una
tensione positiva. Fare riferimento alla sezione relativa il Cablaggio
Morsettiera, morsetti LED e SET.
(Default)
Posizionato su 0V richiede come comando di attivazione un
riferimento negativo di alimentazione 0V. Fare riferimento alla
sezione relativa il Cablaggio Morsettiera, morsetti LED e SET.
Prova di movimento (Walk Test)
Importante:
Dopo aver alimentato il rivelatore, chiudere il coperchio entro 30
secondi per poter effettuare correttamente la fase di calibrazione del circuito di
antimascheramento (AM).
1. Due o tre minuti dopo aver alimentato il rivelatore (inizializzazione) effettuare
la prova di copertura dell'area da proteggere verificando la risposta del rivelatore
tramite l'accensione dei LED (vedere Figura 7).
2. La portata della microonda va regolata tramite l'apposito potenziometro situato
sulla scheda elettronica. Regolare il potenziometro della microonda al minimo
possibile riferito all'area da proteggere (vedere Figura 5).
LED Stato Descrizione
LED
Stato
Descrizione
Giallo
Illuminato
Rilevazione del canale PIR
Lampeggiante
Anomalia del canale PIR
Verde
Illuminato
Rilevazione del canale MW
Lampeggiante
Anomalia del canale MW
Blu
Illuminato
ALLARME
Lampeggiante
Anomalia / Rilevazione circuito Anti-Mask
Nota:
La rilevazione del canale Anti-Mask può essere
attiva solo ad impianto "Disinserito" (Consultare la
sezione del Cablaggio morsettiera, morsetto SET).
All'alimentazione tutti i LED lampeggiano in sequenza
Tutti i LED Lampeggianti
fino alla fine del periodo di inizializzazione (2-3 minuti).
consecutivamente
Alla fine del periodo di inizializzazione il LED ROSSO
continuerà a lampeggiare fino alla fine della fase di
inizializzazione del canale Anti-Mask.
Nota:
L'indicazione di Mascheramento e/o Anomalia persiste fino a quando la
causa non viene rimossa.
Specifiche Tecniche
Elettriche
Assorbimento di corrente
16mA a 12V− (Nominale)
41mA a 12V− (Massimo)
Alimentazione richiesta
da 9V− a 16V−
Contatti di allarme
24V− 0.1A
Contatti Tamper
24V− 0.1A
Contatti FAULT/AM
24V− 0.1A
Ambientali
Immunità RF
Conforme alle norme EN50130-4
Temp. funzionamento
da -10ºC a 55ºC
Temp. stoccaggio
da -20ºC a 60ºC
Ottica
Filtro
Protezione contro le luci bianche
Fisiche
Dimensioni
127.6 mm x 64.2 mm x 46.6 mm
Peso
120 gr.
RISCO Group Contacting Info
RISCO Group is committed to customer
service and product support. You can
contact us through our website
(www.riscogroup.com) or at the following
telephone and fax numbers:
UK Tel: 44-(0)-161-655-5500
support-uk@riscogroup.com
ITALY Tel: +39-02-66590054
support-it@riscogroup.com
SPAIN Tel: +34-91-490-2133
support-es@riscogroup.com
FRANCE Tel: +33-164-73-28-50
support-fr@riscogroup.com
BELGIUM Tel: +32-2522-7622
support-be@riscogroup.com
U.S.A Tel: +1-631-719-4400
support-usa@riscogroup.com
BRAZIL Tel: +55-11-3661-8767
support-br@riscogroup.com
CHINA (Shanghai)
Tel: +86-21-52-39-0066
support-cn@riscogroup.com
CHINA (Shenzhen)
Tel: +86-755-82789285
support-cn@riscogroup.com
POLAND Tel: +48-22-500-28-40
support-pl@riscogroup.com
ISRAEL Tel: +972-3-963-7777
support@riscogroup.com
5IN1600
NEDERLANDS
De Bware DT AM detector is de ultieme bewegingsmelder voor professionele
installaties, met integratie van beide technologieën Anti-Masking en Anti-Cloak™
(ACT™) met ingebouwde end-of-line (EOL) weerstanden voor een eenvoudige
installatie.
De detector maakt gebruik van de K-Band microwave om muur penetratie te
verminderen.
Installatie / Onderhoud
Montage - De BWare DT AM kan op een vlakke oppervlakte worden gemonteerd,
of op een muurhoek (hoekmontage)
1. Verwijder het voorste lid met het juiste gereedschap (zoals beschreven in
Afbeelding 1).
2. Met een passend gereedschap opent u de volgende uitwerpers op de basis
van de detectore (zi Afbeelding 2).
Opmerking:
Als een achterstamper wordt gebruikt, is het verplicht om de
achterplaat van de stamper op de muur (of muurhoek) vast te schroeven.
3. Om voor de brede hoeklens de juiste verticale afstelpositie te selecteren,
gebruikt u de schaal op de rechts onderkant van de PCB lid. U doet dit als
volgt:
Montagehoogte en schaalpositie op basis van kamergrootte:
Montagehoogte
L - LANG
C - KORT
2.1m-2.7m
15m
6m
Opmerking:
Voor installaties in een hal selecteert u de positie naar 'LANG'
en monteert u de detector op een hoogte van 2,5 m/8'2".
4. Jumpers instellen (zie sectie Jumperinstellingen).
Opmerking:
Stel na elke wijziging aan de instellingen, de detector opnieuw in.
5. Installeer het voorste lid terug op zijn plaats (in omgekeerde volgorde van
de verwijdering).
6. Voer een looptest uit (zie sectie Looptest hieronder).
Bedrading terminal (zie Afbeelding 5)
Terminal
Beschrijving
- 12 +
12 VDC-ingang
ALARME
N.C.-relais
TAMPER
N.C. Sabotageschakelaar
FAULT/AM
Normaal gesloten relais: De relais STORING/AM wordt bij de volgende
gebeurtenissen geopend:
• Detectorbewaking wordt ingeschakeld (Relais alarm wordt ook geopend)
• Zelf-test is mislukt
• Ingangspanning is lager dan 8VDC
LED
LED-werking afstandsbediening
Als op de LED van de ingangterminal een "Activeringsignaal"** wordt
toegepast, worden alle LED's uitgeschakeld. LED's worden ingeschakeld
als niks is aangesloten (tenzij LED-jumper op UIT is ingesteld) of 0V/12V
wordt toegepast (volgens de LED/INSTELLING positie van de
ingangjumper, 12 V of 0 V).
SET
Externe besturing INSTELLEN/NIET INSTELLEN
INSTELLEN: als een "activeringsignaal"** wordt toegepast, wordt de anti-
maskeringdetectie uitgeschakeld (voor configuratie Klasse 2).
NIET INSTELLEN: Als niks is aangesloten of als 0 V/12 V wordt toegepast
(volgens de LED/INSTELLING
**Activeringsignaal-
Als 12 VDC wordt toegepast en de ingangjumper LED/INSTELLEN is op de
positie 12V (standaardpositie)
-Of-
0 V wordt toegepast en ingangjumper LED/INSTELLEN is op positie 0 V
Jumperinstellingen
Jumper
Functie
SW1-1: LED
Gebruikt om de werking van de LED's van de detector vast te stellen.
AAN
LED's worden ingeschakeld zodat via de ingangsterminal van de LED,
(Standaard)
LED-besturing mogelijk is.
UIT
LED's worden uitgeschakeld
SW1-2: ACT Gebruikt om vast te stellen of de ACT-modus is in- of uitgeschakeld.
AAN
ACT ingeschakeld
Belangrijk:
Niet de ACT™-modus gebruiken als u verwacht dat er
buiten het beschermde gebied (zoals bijvoorbeeld een hal, bewegende
objecten zijn.
UIT
ACT uitgeschakeld.
(Standaard)
SW1-3: Groene lijn
De Bware DT AM bevat de Groene lijn functie die milieurichtlijnen volgt door een
overschot uitstraling te vermijden. Deze functie schakelt het MW-kanaal uit als het
alarmsysteem "uitgeschakeld" is en dus de overmatige MW-uitstraling vermijdt wanneer
het gebied bezet is.
Groene lijn functie is ingeschakeld: om de MW-module in de periode
"Uitgeschakeld" te deactiveren, moeten ook de LED'S van op afstand
door de LED-terminal worden uitgeschakeld.
AAN
Opmerking:
Als de 'Groene lijn' functie aan is (microgolf uit), is de
detector nog steeds actief (enkel PIR).
UIT
Functie Groene lijn is uitgeschakeld: MW is constant in gebruik
(Standaard)
SW1-4: Zelf
Gebruikt om detectietechnologieën te testen.
Test
(Lokale zelftest): als in het PIR-kanaal gedurende 1 uur geen
AAN
alarmdetectie plaatsvindt, voert de detector een zelftest uit. Als de
lokale zelftest mislukt, wordt de STORING/AM-relais actief.
(Externe zelftest): de externe zelftest wordt geactiveerd als de terminal
UIT
INSTELLEN van de modus INSTELLEN naar NIET INSTELLEN
(Standaard)
schakelt. Opdat de externe zelftest slaagt, zal de alarm-relais gedurende
5 seconden actief zijn.
Jumpers J1 en J2 maken de selectie mogelijk voor sabotage- en
J1 - Alarm EOL
alarmweerstand (1K, 2.2K, 4.7K, 5.6K, 6.8K) volgens het
J2 - Sabotage EOL
bedieningspaneel (zie Afbeelding 4). Met jumper J3 is de selectie
J3 - STORING/
mogelijk van 12K voor Storing/Anti-maskering.
AM EOL
Volg het aansluitingsschema van het aansluitblok in Afbeelding
4 als u de detector op een twee-/drievoudige zone aan het einde
van de lijn (DEOL/TEOL) aansluit.
J4 - LED/
INSTELLEN
Gebruikt om de polariteit van de externe ingang vast te stellen.
INGANG
Zie de sectie Bedrading terminal, terminals LED en INSTELLEN
(Standaard)
Zie de sectie Bedrading terminal, terminals LED en INSTELLEN

Publicidad

loading

Resumen de contenidos para RISCO Group BWare RK515DTG3

  • Página 1 RISCO Group Limited Warranty RISCO Group Contacting Info U.S. Patent Number: RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products RISCO Group is committed to customer This product is protected under Patent No. US 7,126,476 B2. to be free from defects in materials and workmanship under normal use for 24 service and product support.
  • Página 2 2. O alcance de Microondas deve ser ajustado usando-se o potenciômetro, que dekking te bieden (zie Afbeelding 5). Nota: Todos os detectores da RISCO Group que possuem o sistema de está localizado no PCB. É importante colocar o potenciômetro na configuração ACT Habilitado anti-máscara através de Infravermelho Ativo, possuem uma proteção contra luz...