• The measurements taken by you are for your information
only – they are not a substitute for a medical examination!
Discuss the measurements with your doctor, and never base
any medical decisions on them (e.g. medicines and their
administration)!
• Using the blood pressure monitor outside your home envi-
ronment or whilst on the move (e.g. whilst travelling in a car,
ambulance or helicopter, or whilst undertaking physical ac-
tivity such as playing sport) can influence the measurement
accuracy and cause incorrect measurements.
• Do not use the blood pressure monitor on newborns or pa-
tients with preeclampsia. We recommend consulting a doctor
before using the blood pressure monitor during pregnancy.
• Cardiovascular diseases may lead to incorrect measure-
ments or have a detrimental effect on measurement ac-
curacy. The same also applies to very low blood pressure,
diabetes, circulatory disorders and arrhythmias as well as
chills or shaking.
• The blood pressure monitor must not be used in connection
with a high-frequency surgical unit.
• Only use the device on people who have the specified upper
arm measurement for the device.
• Please note that when inflating, the functions of the limb in
question may be impaired.
• During the blood pressure measurement, blood circulation
must not be stopped for an unnecessarily long time. If the
device malfunctions, remove the cuff from the arm.
• Avoid any mechanical restriction, compression or bending of
the cuff line.
All manuals and user guides at all-guides.com
• Do not allow sustained pressure in the cuff or frequent meas-
• Ensure that the cuff is not placed on an arm in which the
• Do not use the cuff on people who have undergone a mas-
• Do not place the cuff over wounds as this may cause further
• You can either use the blood pressure monitor with batteries
• To conserve the batteries, the monitor switches off automati-
• The device is only intended for the purpose described in
• The blood pressure monitor is made up of precision electron-
18
urements. The resulting restriction of the blood flow may
cause injury.
arteries or veins are undergoing medical treatment, e.g. intra-
vascular access or therapy, or an arteriovenous (AV) shunt.
tectomy.
injury.
or with a mains part. Please note that data transfer and data
storage is only possible when your blood pressure monitor is
supplied with power. As soon as the batteries are empty or
the mains part is disconnected from the power supply, the
blood pressure monitor loses the date and time.
cally if no buttons are pressed for 3 minutes.
these instructions for use. The manufacturer is not liable for
damage resulting from improper or careless use.
Storage and Care
ic components. Accuracy of readings and the instrument's
service life depend on careful handling.
– You should protect the device from impact, moisture, dirt,
major temperature fluctuations and direct exposure to the
sun's rays.
– Never drop the device.