This air compressor pump is capable of running continuously. However, to prolong
the life of your air compressor, it is recommended that a 50%-75% average duty
cycle be maintained; that is, the air compressor pump should not run more than
30-45 minutes in any given hour.
UNPACkING
1.
Remove unit from carton and discard all packaging.
HOW TO SET UP YOUR UNIT
LOCATION OF THE AIR COMPRESSOR
Locate the air compressor in a clean, dry and well ventilated area.
The air compressor should be located at least 12" (30.5 cm) away from the
wall or other obstructions that will interfere with the flow of air.
Place the air compressor on a flat level surface in the vertical position resting
on the rubber bumpers and wheels
The air compressor pump and shroud are designed to allow for proper cool-
ing. The ventilation openings on the compressor are necessary to maintain
proper operating temperature. Do not place rags or other containers on or
near these openings.
GROUNDING INSTRUCTIONS
Risk of Electrical Shock. In the event of a short circuit, ground-
ing reduces the risk of shock by providing an escape wire for the electric cur-
rent. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with
an appropriate grounding plug (see following illustrations).
1.
The cord set and plug with this unit contains a grounding pin. This plug
MUST be used with a grounded outlet.
IMPORTANT: The outlet being used must be installed and grounded in accordance
with all local codes and ordinances.
2.
Make sure the outlet being used has
the same configuration as the ground-
ed plug. DO NOT USE AN ADAPTER.
See illustration.
3.
Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
4.
If these grounding instructions are
not completely understood, or if in doubt as to whether the compressor is
properly grounded, have the installation checked by a qualified electrician.
Risk of Electrical Shock. IMPROPER GROUNDING CAN
RESULT IN ELECTRICAL SHOCk.
Do not modify the plug provided. If it does not fit the available outlet, a correct
outlet should be installed by a qualified electrician.
Repairs to the cord set or plug MUST be made by a qualified electrician.

DUTY CYCLE

ASSEMBLY

INSTALLATION

Grounding Pin
9 - ENG
Plug
Grounded
Outlets