Power cord (AXRF RF Subsystem only)
When the equipment has to be plugged into a Class II (ungrounded) two-terminal socket outlet, the
cable should either be fitted with a three-pin Class I plug and used in conjunction with an adapter
incorporating a ground wire, or be fitted with a Class II plug with an integral ground wire.
Fasten the ground wire securely to ground. If you ground one terminal on a two-terminal socket, it
does not provide adequate protection.
If a molded plug has to be removed from a lead, dispose of it immediately. A plug with bare flexible
cords is hazardous if it is inserted into a live socket outlet.
The power cord is the equipment's disconnecting device.
Use the supplied power cord or an appropriate replacement. The power cord set must be an
appropriately rated and approved cord set in accordance with the regulations of the country it is
used in. Do not replace a detachable power cord with an inadequately rated cord.
Standby/on switch
The switch on the front panel of the AXRF RF Subsystem is a standby switch only, and does not
isolate the equipment from the supply. Remove the power cord from the socket outlet to isolate the
equipment.
Electrostatic discharge (ESD)
If you are connecting cables that are not already connected to equipment at either end, make sure
that any static electricity in the cable is first discharged to ground.