Replacing the batteries
Replace the old batteries with new ones
when the following cases, which signify
exhausted batteries, occur:
• There is no beep sound when a signal is
transmitted.
• Received indicator fades away.
The remote control is powered by 2 dry
batteries (R03/LR03X2) in the back part of
the remote, protected by a cover.
1. Remove the cover in the back part of the remote control.
2. Remove the old batteries and insert the new batteries, placing the
(+) and (-) poles correctly.
3. Place the cover back on.
NOTE: When the batteries are removed, the remote control erases
all programming. After inserting new batteries, the remote control
must be reprogrammed.
CAUTIONS
• Do not mix old and new batteries or different types of batteries.
• Do not leave the batteries in the remote control if they are not going
to be used for 2 or 3 months.
• Do not dispose of batteries as unsorted municipal waste. It is
necessary to collected such waste separately for special processing.
Exhaust hose installation
The exhaust hose and adaptor must be installed or removed in
accordance with the usage mode. For the COOL mode, the exhaust
hose must be installed. For the FAN or DRY modes, the exhaust
hose must be removed.
Operation Instructions
COOL operation
- Press the MODE button until the COOL indicator light comes on.
- Press the ADJUST buttons "+" or "-" to select your desired room
temperature. The temperature can be set within a range of 17°C ~
30°C / 62°F ~ 86°F (or 88°F).
- Press the FAN SPEED button on the remote control to choose the
fan speed
DRY operation
- Press the MODE button until the DRY indicator light comes on.
- Under this mode, you cannot select a fan speed or adjust the
temperature. The fan motor operates at LOW speed.
36
portable air conditioner
- Keep windows and doors closed for the best dehumidifying effect.
- Do not duct tape the window.
FAN operation
- Press the MODE button until the FAN indicator light comes on.
- Press the FAN SPEED button on the remote control to choose the
fan speed. The temperature cannot be adjusted.
- Do not duct tape the window.
Other features
SLEEP (ECO) operation
This feature can only be selected with the remote control. To activate
the SLEEP feature, the set temperature will increase by 1°C / 2° F
(or 1°F) in 30 minutes. The set temperature will then increase by
another 1°C / 2°F (or 1°F) after an additional 30 minutes. This new
temperature will be maintained for 7 hours before it returns to the
originally selected temperature. This ends the Sleep/Eco mode and
the unit will continue to operate as originally programmed.
NOTE: this feature is unavailable under the FAN or DRY modes.
FOLLOW ME / TEMP. SENSING feature
NOTE: this feature can be activated from the remote control ONLY.
The remote control serves as a remote thermostat allowing for the
precise temperature control at its location. To activate the Follow Me/
Temp. Sensing feature, point the remote control towards the unit and
press the Follow Me/Temp. Sensing button. The remote control will
send this signal to the air conditioner until press the Follow Me/Temp.
Sensing button again. If the unit does not receive the Follow Me/
Temp. Sensing signal during any 7 minutes interval, the unit will exit
the Follow Me/Temp. Sensing mode.
NOTE: this feature is unavailable under the FAN or DRY modes.
AUTO-RESTART
If the unit breaks off unexpectedly due to the power cut, it will restart
with the previous function setting automatically when the power
resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped or turned off accidentally, its operation
cannot restart for 3 minutes. This happens to protect the unit.
Operation will automatically resume after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
Adjust the air flow direction manually:
- The louver can be set to the desired position manually.
- Do not place any heavy objects or other loads on the louver; doing
so will cause damage to the unit.
- Ensure the louver is fully opened under heating operation.
- Keep the louver fully open during operation
37
EN
KAC4254