SATA clean RCS Instrucciones De Servicio página 48

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Operating instructions SATA clean RCS
All manuals and user guides at all-guides.com
4. Turn functional switch (4) to „Cleaning". Thus, the spray air is reduced
to a minimum and, at the same time, the cleaning brush is activated.
5. Pull gun trigger and move paint channel (cup connection) area up and
down along the cleaning brush. Thus, the cleaning brush will automa-
tically clean the air cap as well. The anti-splash system (6) prevents
cleaning agent from splashing uncontrollably from the SATA clean
RCS.
6. Turn functional switch (4) into position "Drying".
In the second chamber, purge cleaning fluid from the outside and the paint channel area
of the paint spray gun, while trigger is pulled, by activating the button (5) "Drying".
For this purpose, move gun to and fro under the blowing nozzle and briefly pull the trig-
ger.
7. The paint spray gun is now cleaned and ready for the next paint job.
Turn functional switch into position "Spraying".
USA / Canada: After cleaning, close the drilling in the runoff plate (15)
by means of the closing plug.
The deposit surface (1) may be used for putting down objects such as,
e.g., RPS cups!
8. Adjusting the pressure regulators
1. Adjust the cleaning agent quantity during cleaning.
2. Adjust the low air volume required for cleaning at the paint spray gun.
Attention: The air volume must be as low as possible!
The pressure regulators are adjusted to a fixed value and tuned during production,
and should not be readjusted. In case of faulty adjustments cleaning agent could
splash out of the appliance.
VIII.4
1.
2.