Descargar Imprimir esta página

KPS MT440 Manual De Instrucciones página 2

Multímetro digital
Ocultar thumbs Ver también para MT440:

Publicidad

Idiomas disponibles

Idiomas disponibles

Overview
This is a stable, safe, reliable compact digital handheld 4000 count, auto-ranging multimeter.
This meter can measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency,
duty cycle, diodes and continuity. NCV and circuit connection tests.This meter is ideal for
many situations, whether you're a professional or causal user.
Safety lnformation
WARNING
Please particularly note that inappropriate use may cause shock or damage to the meter.
When using, comply with common safety procedures and completely follow the safety
measures stated in the operation manual.
In order to make full use of the meter's functions and ensure safety operation, please
carefully read and follow the use methods in the operation manual.
The meter meets EN61010-1, EN61010-2-032 safety requirements for electrical testing
instruments and handheld digital multimeters. lt's designed to comply with a CAT IV 600V
safety rating and pollution degree of 2. Please follow the safety operation guidelines to
ensure the safe use of meter. The meter will provide satisfactory service to you if you use
and protect it appropriately.
Preparation
When using the meter, the user should comply with standard safety rules:
- General shock protection
- Prevent misusing the meter.
• Please check for damage that may have occurred during transportation after receiving
the meter.
• lf it should be stored and shipped under hard conditions, please confirm if the meter is
damaged.
• Probe should be in good condition. Before use, please check whether the probe insulation
is damaged and whether metal wire is bare (not properly insulated).
• Use the probe table provided with the meter to ensure safety. lf necessary, it should be
replaced with another identical probe or one with the same capacity.
Usage
• When using, select the correct function and measuring range.
• Don't exceed the indicated maximum of each measuring range.
• When measuring circuits with the meter connected, do not touch the probe tip (metal part).
• When measuring, if the voltage to be measured is more than 60 V OC or 30 V AC (RMS),
always keep your fingers always behind finger protection device.
• Don't measure voltage greater then 600 V.
• For manual measuring range, when the value to be measured is unknown, select the
highest measuring range.
• Before rotating conversion switch to change measuring function, remove probe from the
circuit to be measured.
• Don't measure resistors, capacitors, diodes and circuit connections with power.
• During tests of current, resistors, capacitors, diodes and circuit connections, avo id
connecting the meter with voltage sources.
• Do not measure capacitance befare capacitor is discharged completely.
• Do not use the meter in explosive gas, vapor or dusty environments.
• lf you find any abnormal phenomena or failure on the meter stop using it inmediately.
• Do not use the meter unless the bottom case and the battery cover are completely
fastened in their original places.
• Don't store or use the meter in direct sunlight or high temperature and high humidity
conditions.
Maintenance
• Don't try to open the meter bottom case to adjust or repair. Such operations only can
be operated by technicians who fully understand the meter and electrical shock hazard.
• Before opening the meter bottom case or battery cover, it should remove probe from the
circuit to be measured.
• To avoid incorrect readings and possibly causing electric shock when
meter display, replace the battery immediately.
• Clean the meter with damp cloth and mild detergent. Do not use abrasives or solvents.
• When the meter is not used, switch the measuring range to OFF position.
• lf the meter is not u sed far long time, remove the battery to prevent damage to the meter.
WARNING
Protection impairment if used in a manner not specified by the manufacturer.
Replace battery
WARNING
Before opening the meter battery cover, remove probe from the circuit to be measured to
avoid electric shock.
• When the battery indicator
appears, the battery should be replaced immediately.
• Unscrew the fastening screw of the meter battery cover and remove it.
• Replace the 9V 6F22 battery.
• lnstall the battery cover
Note: The battery polarity can't be reversed.
ENG
ENGLISH
Replace Probe
Repl ace probe if leads become damaged or worn.
Use meet EN 61010-031 standard, rated CA better probes.
Replace fuse
• Fuse specifications:
- F1:FF 400mA H 1000V
- F2: FF 10A H 600V
• Replacing the defective fuse should the done according to the following procedure:
- To avoid electrical shock,remove the test lead and any input signa! before opening
the bottom case.
- Remove the battery cover and remove the three screws from the bottom case.
- Lift the button case until it gently unsnaps from the top case.
- Remove the defective fuse and inserta new fuse of the same size and rating.
- Replace the bottom case and reinstall ali the screw.
Accessories
• Probe
• Summary instruction manual
• 9V 6F22 battery
instruction manual:
appears on the
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
info.emea@mgl-intl.com
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
Digital multimeter
WARNING
1 pair
1 pc.
1 pc.
See the full
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
KPS SOLUCIONES EN ENERGÍA, S.L.
Tel: +1 833 533-5899
Parque Empresarial de Argame,
US West Coast: 760 Challenger Street.
C/Picu Castiellu, Parcelas i-1 a i-3
Brea, California 92821 USA
E-33163 Argame, Morcín
Tel: +1 310-728-6220
Asturias, España, (Spain)
www.mgl-intl.com
ENG

Publicidad

loading

Este manual también es adecuado para:

Kpsmt440cbint