Step 2: Install drain joint (Heat pump
unit only)
Before bolting the outdoor unit in place, you
must install the drain joint at the bottom of
the unit. Note that there are two di erent
types of drain joints depending on the type
of outdoor unit.
If the drain joint comes with a rubber seal
(see Fig. A ), do the following:
Fit the rubber seal on the end of the drain joint
1.
that will connect to the outdoor unit.
Insert the drain joint into the hole in the base
2.
pan of the unit.
Rotate the drain joint 90° until it clicks in place
3.
facing the front of the unit.
Connect a drain hose extension (not included)
4.
to the drain joint to redirect water from the
unit during heating mode.
If the drain joint doesn't come with a rubber
seal (see Fig. B ), do the following:
Insert the drain joint into the hole in the base
1.
pan of the unit. The drain joint will click in
place.
Connect a drain hose extension (not included)
2.
to the drain joint to redirect water from the
unit during heating mode.
Seal
Seal
Drain joint
(A)
Page 26
Base pan hole of
outdoor unit
(B)
IN COLD CLIMATES
In cold climates, make sure that the drain
hose is as vertical as possible to ensure
swift water drainage. If water drains too
slowly, it can freeze in the hose and ood
the unit.
Step 3: Anchor outdoor unit
The mounting dimensions vary among
di erent outdoor units.
The xing bolt head diameter should be
more than 12mm.
W
D
A
Outdoor unit A
Outdoor Unit Dimentsion (mm)
W
H
D
952
1333
415
900
1170
350
A1
D
Outdoor unit B
Outdoor Unit Dimentsion (mm)
W
H
D
1128
1555
426
H
B
Mounting Dimentsion (mm)
B
A
634
404
590
378
A2
B
Mounting Dimentsion (mm)
A2
A1
B
668
206
494