Connecting An Egc-Compatible Device; Connect The Units To The Power Supply Distributor - Oase FM-Master WLAN Instrucciones De Uso

Ocultar thumbs Ver también para FM-Master WLAN:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 153
- EN -
5.4

Connecting an EGC-compatible device

The correct fastening of the plug connector is important for a secure connection and an interference-free EGC
network.
An EGC connection cable is necessary for connection.
The EGC connection cable is available as an accessory in the lengths 2.5 m (47038), 5 m (47039) and 10 m
(47040).
How to proceed:
 G, H
1. Remove the terminal resistor from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
Ensure that the rubber seal is clean and fits exactly.
Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT of the last unit in the EGC network, fit the terminal resistor and
secure it with the two screws (max. 2.0 Nm).
No EGC connection cable is connected to EGC-OUT on the last unit in the EGC network. The terminal re-
sistor has to be fitted to this EGC-OUT so that the EGC network is correctly terminated.
The terminal resistor is included in the delivery scope of the InScenio FM-Master WLAN EGC.
N O T E
For further information regarding the operation and integration into the EGC system, please refer to
the instructions for use of the FM Master WLAN EGC at http://www.oase-livingwater.com/egc-start.
5.5

Connect the units to the power supply distributor

Only connect one unit per socket.
Do not connect any InScenio controllers or portable multiple sockets to the unit.
How to proceed:
1. Choose a suitable socket (see fig. above) and insert the unit power plug into the socket.
Ensure that it is permissible to connect the unit to this socket. For this purpose, consult the operating man-
ual of the unit you wish to connect.
Units powered via a transformer may not be connected to the socket with the dimmer function.
EGC-capable units may not be connected to the socket with the dimmer function.
 I
2. Fit the protection hood.
48
1 Socket 1, switchable (max. 10 A / 2000 W)
2 Socket 2, switchable (max. 10 A / 2000 W)
3 Socket 3, switchable (max. 10 A / 2000 W)
4 Socket 4, switchable and dimmable (40 W ... 320 W)
Note: Ensure that the total output of 16 A / 3600 W is not exceeded!

Publicidad