INSTALLATION CON'T.
4. Connecting the Natural Gas Supply Line
NOTE: A licensed plumber should be used to install the gas supply line to the grill.
The gas supply line from your home should be routed to the right rear corner of the grill inside the grill enclosure. It is recommended
that hard piping be used to connect to the inlet of the natural gas appliance regulator. Constant movement of flexible gas lines could
cause fatiguing of the flexible line and result in gas leakage. If hard piping is not used for the home supply line, any flexible gas lines
must be supported within the enclosure to prevent constant movement and fatiguing.
Prior to installing the grill in the enclosure:
1. Turn the home gas source to the OFF position.
2. Remove the plastic protective cap from the ½"pipe fitting connection found at the bottom of the right rear corner of the grill (see
Figure 5 ).
3. Apply pipe joint compound (not provided) to the ½" pipe fitting connection. The pipe joint compound used should be resistant to all
gasses.
4. Connect the natural gas appliance regulator (provided) to the ½"pipe fitting connection taking care to connect the outlet side of the
regulator to the pipe fitting connection (see Figure 6 ). The inlet and outlet sides of the regulator are noted by markings on the rear
of the regulator body.
All manuals and user guides at all-guides.com
Figure 5
Side View
Figure 6
Side View
½" Pipe Fitting
½" Pipe Fitting
Regulator
13