23. With clean water in the clean Tank, spray water
through the Hose, Shutoff, Wand, and Nozzle for
at least 30 seconds to rinse them out. Failure to
rinse out the Hose, Shutoff, Wand, and Nozzle
may allow chemical residue build-up that can
clog or damage the components. After heavy
use rinsing the Nozzle may not be enough to
remove residue. The Nozzle may need to be
cleaned with a small brush.
24. Press the Power Button to turn off the Pump.
25. Operate the Pressure Release Valve on the side of
the Tank to release pressure.
26. Remove the Pump. Avoid placing the Pump
down where it may become contaminated with
dirt, grass clippings, or debris that could later
enter the Tank.
27. Open the Shut-off (depress Lever) to drain any
remaining water from the Hose, Shut-off, and
Wand.
28. Empty out any remaining water from the Tank.
29. Allow the Sprayer to dry. This is best done by
hanging the Tank upside down to let it drain.
30. Once the Sprayer is dried turn the Sprayer
upright and loosely assemble the Pump to the
Tank to prevent debris from entering the Tank.
31. Store the Sprayer, Pump, and Charger indoors in
a warm, dry location out of direct sunlight and
away from any sources of moisture or intense
heat. Do not store Sprayer where freezing
temperatures (below 32°F/0°C) will occur.
Allowing water to freeze inside the Sprayer
may damage the Pump, Seals, Shutoff, or other
components, and void the Sprayer warranty.
32. To ensure optimal Battery life the Battery should
be charged at least once every 3 months when
not in use. See Charging the Pump Internal
Battery.
8

MAINTENANCE

WARNING: Prior to performing maintenance always
depressurize Sprayer by pressing the Power Button
to turn power OFF and then operating the Pressure
Release Valve until all air pressure in the Tank has
been released.

Nozzle Maintenance

1. If nozzle clogs, remove and disassemble the
nozzle assembly.
2. Clean the openings of any obstructions and
reassemble.
3. The brass nozzles should be cleaned with
toothbrush and a detergent. Don't use a metal
brush or sharp objects on the nozzle. For tough
clogs soak brass nozzle in xylene and clean with
a brush.

Shut-off Maintenance (Repair Kit)

WARNING: Always depressurize sprayer before
maintenance by activating shut-off and spraying
contents out.
1. Unscrew the handle from the shut-off assembly.
2. Unscrew valve cap and remove valve stem
components and seals as shown. Clean
components with cool clean water.
3. Clean any debris from inside the handle and
shut-off body. Check for any wear of O-rings or
seals (1) and replace as necessary.
4. Reassemble the components as shown and
tighten the handle and valve cap securely.
Shutoff Service Kit #182906