Connect the pond pump to the mains supply, plug the mains plug into the socket outlet.
The pond pump pumps the contaminated water into the filter through the UVC emitter
Connect the UVC emitter to the mains supply, plug the mains plug into the socket outlet.
You can check the function of the UVC tube through a bluish shimmer on the transparent discharge port of
the UVC emitter.
For this filter system we recommend continuous operation (24 hours a day), in the season months March to
October.
Note: - The biological filtration develops naturally, it takes 5-6 weeks until the full
effect is attained. To accelerate settlement of bacteria, appropriate bacteria can be purchased in any pond
shop.
Attention! The function of the filter system must be checked at regular intervals!
Initially the filter system should be checked at least 1x daily. Leaves, grass, and animal hair, for example can
quickly clog the filter sponges.
Consequently select the cleaning intervals based on the type and the extent of contamination in your pond.

6. Maintenance and care

Attention! Prior to carrying out any maintenance work, the electric device must be separated from the
electrical mains.
Attention! The power cord of this device cannot be replaced. If the cable is damaged the UVC emitter
contained in the filter, including the ballast, is unusable and must be properly disposed of. Repair is not
possible because the connecting lines are permanently cast.
6.1.
Cleaning the pump
− always disconnect the power supply before performing any maintenance work
− make sure the pump's filter is not entirely clogged by leaves or other debris. If it is, clean the housing.
1. Press the side of the front cover (40) and pull it off the pump (Fig. 1)
2. Remove the inlet cover (42) by releasing the 4 screws (41) and remove (fig. 1).
3. Pull the inlet cover (42) off the pump carefully.
4. Pull the rotor (46) completely out of the pump.
5. Clean the impeller and the housing (49) well with clear water and a soft cloth.
6. Mount the pump as follows:
6.1 Check whether the O-ring (45) is in the correct position.
6.2 Replace the O-ring if damaged.
6.3 Insert the rotor (46) into the pump completely.
6.4 Check that the rotor retaining plate is tight and locked into place.
6.5 Fit the inlet cover (42) to the pump carefully and attach with 4 screws (41).
6.6 Insert the front cover (40) into the pump.
For proper operation, repeat this procedure depending on the degree of soiling and service life.
6.2.
Cleaning the UVC emitter and replacing the tube
Caution! Do not touch UVC tube (31) directly with your hand; put on cotton gloves!
Old UV-C tubes shall not get broken and must not be disposed in regular garbage bin. Contact your local
waste disposal company. Do not use a sharp edged tools. In case Quartz glass cylinder or O-ring are defect,
they should get replaced immediately.
The lamp must be changed by qualified personnel only.
If you notice an increase in algae formation and/or see that lime scale is increasing, you will need to check
that the UV-C unit is working properly. UVC tube has a limited period of effectiveness (approx. 4000 to 5000
hours) and should be replaced at the latest after one season (March to October). Appropriate replacement
tubes are available at the service address specified below.
If the pond filter has been switched off for a longer period of time, ensure that the quartz glass cylinder that
encloses the UVC tube is clean.
If the filter has not been operated for a longer period of time, under some circumstances it may be necessary
to replace the sealing rings (particularly for the UVC emitter).
Cleaning of the UV-C lamp
1. Disconnect the UVC lamp from the mains power and safeguard it from being switched on unintentionally
2. Comply with the safety measures.
3. Allow the water to completely run out of the unit.
14