4. TECHNICAL SPECIFICATIONS

4.1 General specifications

- Environment conditions:
CAT. II 1000V and CAT. III 600V
Pollution degree: 2
Altitude < 2000 m
Operating temperature:
0ºC~40ºC, 32ºF ~122ºF (<80% RH, <10ºC non-condensing)
Storage temperature:
- 10ºC ~60ºC, 14ºF ~140ºF (<70% RH, battery removed)
- Temperature Coefficient:
0.1(specified accuracy) / ºC (<18ºC or >28ºC)
- Operating principle: dual slop integration
- Sample Rate: 3 times/sec.
- Display: 3 1/2 digits LCD display. Automatic indication of functions and symbols.
- Range selection: autorange.
- Over Range indication: LCD will display "OL".
- Polarity indication: "-" displayed automatically.
- Jaw opening capability: 55mm.(Maximum conductor size)
- Low battery indication:
The "
" is displayed when the battery is under the proper operation range.
- Power source: 9V
- Battery type: 6F22 or equivalent.
- Dimensions : 260(L) x110 (W)x 42(H) mm.
- Weight: 480g. Approx. (battery included).