Descargar Imprimir esta página

CasaFan AEROPLAN ECO Instrucciones De Montaje página 8

Publicidad

- Before accessing the connection and installation, the current
must be disconnected on all poles (fuse in fuse box).
- Children shall not play with the appliance.
- Ensure that the fan is switched off from the supply mains before
service and maintenance.
- The electrical connection and electrical maintenance of this fan
may only be carried out by a trained electrician, a skilled electri-
cian or an appropriately qualified person.
- The voltage details on the rating label are to conform with the
available mains voltage.
- Do not run the cables over sharp edges and under no circum-
stances squeeze the cables during installation.
- Only operate the ceiling fan when completely assembled!
- WARNING! The mains connection requires a two-pole isolating
switch with a contact opening width of at least 3 mm. The dis-
connecting device must be integrated into the fixed wiring accor-
ding to the valid technical regulations.
- The electrical safety of the fan is only guaranteed if the earthing
system of the building installation is installed in accordance with the
regulations and the fan is connected to it.
- The mains connection to which the fan is connected must comply
with the applicable local standards.
- Choose a safe place for installation and make sure that there are
no objects within the area of rotation.
- The construction and fixture of the holder and ceiling is to be able
to bear 4 times the weight of the fan when being moved.
- None of the fan blades are to be less than 2.3 m from the ground.
- Keep the fan away from heat sources. The minimum distance to
radiant heaters and stoves is 1.5 m.
- Before first using after the setup, all electrical and mechanical
connections are to be checked in order to prevent any fall, fire or
electric shock.
8

Publicidad

loading