Clock output frequency setting (1)
You can set the clock frequency output from the CLOCK OUT connectors.
0 This unit has 3 pairs (A, B and C) of clock outputs that can be sepa-
rated further into 6 individual outputs (A1, A2, B1, B2, C1 and C2).
You can set the clock frequency independently for each of these
outputs.
0 By default, the A, B and C outputs are set to be used as pairs.
Setting A, B and C outputs by pair (default)
When you change the A setting, the output frequency is set for
both A1 and A2 simultaneously.
Likewise, setting B or C affects B1 and B2 or C1 and C2, respectively.
When "A >", "B >" or "C >" appears, pressing the A, B or C button
changes the output frequency of that pair. Press repeatedly to
cycle through the options.
0 Press and hold the A, B or C button for at least two seconds to set
A2, B2 or C2, respectively. (See "Setting A2, B2 or C2" on the right.)
0 If you do not press any buttons for 10 or more seconds, setting
mode will end and the display will return to normal. (If DISP is
set to SHORT, this will happen after 3 seconds.)
If you connect this unit to devices from other manufacturers, be
sure to read the manuals of those devices to confirm the clock fre-
quencies that they can receive.
Some devices require the clock frequency to be set to the same
value as the audio signal sampling frequency.
Some dual AES connection might require that the clock frequency
be set to half of the audio signal frequency.
Setting A1, A2, B1, B2, C1 and C2 independently
Press the A button for at least two seconds until "A2>" appears.
Then, press the A button to change the A2 setting. You can set
different clock frequencies for A1 and A2. The same is true for the
B and C pairs.
Setting A1, B1 or C1
When A2 is set to any value that is not the same as the A1 setting,
when "A1>" appears, press the A button to change just the A1
output frequency. Follow the same procedure for B1 and C1.
Setting A2, B2 or C2
Press 2 or more seconds
Press the A, B or C button for at least two seconds to set A2, B2
or C2.
When "A2>" appears, press the A button to change just the A2
output frequency. Follow the same procedure for B2 and C2.
0 To set A1 after setting A2, press the A button again after return-
ing to the ordinary display.
0 If you set A2 to the same value as A1, "A" will appear again, and
you can set the output frequency used by both outputs in the
A pair simultaneously. Follow the same procedure for B and C
pairs. (See "Setting A, B and C outputs by pair" on the left.)
11