Technical data
6.3.5 Menu level 4: Default setting
You can return the parameters you set in configuration mode on menu lev-
els 1 to 3 to the default settings:
➤ Start configuration mode (see chapter "Start and end configuration
mode" on page 33).
✓ The first digit of the display (see fig. 10 on page 6, Pos. 5) shows the
menu level and the second and third show the parameter which can
be set.
➤ Press the + button (see fig. 10 on page 6, 6) three times to switch to
menu level 4.
✓ The digital display shows
➤ Press the operating mode button (see fig. 10 on page 6, Pos. 4) to
return the system to its default settings.
✓ The digits in the display
➤ Press the + button.
✓ The digital display shows
➤ Press the operating mode button (see fig. 10 on page 6, Pos. 4) to
confirm your entry.
✓ The parameters set in configuration mode are returned to the default
setting.
✓ You are now in menu level 4 and can use the + and - buttons to switch
between menu levels.
7
Technical data
Item number
Cooling capacity:
Rated input voltage:
Input voltage range:
Average current consumption:
Low-voltage cut-off:
Dimensions (L x W x H in mm):
Weight (without balance plate):
Versions, technical modifications and delivery options reserved.
36
All manuals and user guides at all-guides.com
--
.
--
flash.
00
.
Roof air conditioner CoolAir CA-800
CA-0800-DC
800 W
24 V DC
20 V DC – 30 V DC
12 – 22 A
Configurable (see chapter "Menu level 2: Low-
voltage cut-off" on page 34)
690 x 565 x 209 (XF95), 195 (XF105)
(Height above vehicle roof)
20 kg