hood is to be fixed.
• Fixing the decorative telescopic flue
take care not to scratch the duct; wear gloves when removing
the protective film. (Fig. 3).
Arrange the electrical power supply within the dimensions of
the decorative flue. If your appliance is to be installed in the
ducting version or in the version with external motor, prepare
the air exhaust opening. Adjust the width of the support
bracket of the upper flue (Fig.4). Then fix it to the ceiling using
the screws A (Fig.4) in such a way that it is in line with your
hood and respecting the distance from the ceiling indicated
in Fig.2. connect the flange C to the air exhaust hole using a
connection pipe (Fig.5). Insert the upper flue into the lower
flue and rest above the frame. Extract the upper flue up to the
bracket and fix it with the screws B (Fig.4).
To transform the hood from a ducting version into a filtering
version, ask your dealer for the charcoal filters and follow the
installation instructions.
• Filtering version
Install the hood and the two flues as described in the
paragraph for installation of the hood in ducting version. To
assemble the filtering flue refer to the instructions contained
in the kit. If the kit is not provided, order it from your dealer
as accessory. The filters must be applied to the suction unit
positioned inside the hood. They must be centred by turning
them 90 degrees until the stop catch is tripped (fig. 8).
USE AND MAINTENANCE
• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air.
The effective performance of the cooker hood depends on
constant maintenance; the anti-grease filter and the active
carbon filter both require special attention.
• The anti-grease filter is used to trap any grease particles
suspended in the air, therefore is subject to saturation (the
time it takes for the filter to become saturated depends on
the way in which the appliance is used).
- To prevent potential fire hazards, the anti-grease filters should
be washed a minimum of every 2 months (it is possible to use
the dishwasher for this task).
- After a few washes, the colour of the filters may change. This
does not mean they have to be replaced.
If the replacement and washing instructions are not followed,
the anti-grease filters may present a fire hazard.
• The active carbon filters are used to purify the air which
is released back into the room. The filters are not washable
or re-usable and must be replaced at least once every four
months. The active carbon filter saturation level depends on
the frequency with which the appliance is used, the type of
cooking performed and the regularity with which the anti-
grease filters are cleaned.
• Clean the cooker hood frequently, both inside and outside,
using a cloth which has been dampened with denatured
alcohol or neutral, non-abrasive liquid detergents.
• The light on the cooker hood is designed for use during cook-
ing and not for general room illumination. Extended use of the
light reduces the average duration of the bulb.
•Commands:(fig.6)mechanical the key symbols are explained
below:
A = LIGhT
B = OFF
C = SPEEd I
D = SPEEd II
E = SPEEd III
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE
ABOVE WARNINGS.
- 19 -