BACTERIA:
All bacteria use an enzyme as a form of 'chemical lung' in
order to metabolize oxygen. Silver ions cripple the enzyme
and stop the take up of oxygen. This effectively suffocates any
bacteria, killing it within 6 minutes and leaving surrounding
tissue or material unaffected.
VIRUSES:
Viruses grow by taking over another living cell and
reprogramming the nucleus to replicate the virus rather
than the healthy cell. As part of this process, the cell reverts
to a more primitive form that relies upon a primitive form
of oxygen metabolizing enzyme as a chemical lung. Again
the silver ions stop oxygen being brought into the virus-
producing cell and it dies by suffocation.
FUNGUS:
A fungus is composed of a series of single cells. Each cell
survives by means of a 'chemical lung' much like that seen in
bacteria. Just like bacteria, the presence of silver ions disables
the chemical lung and the fungus dies
D) DEMINERALIZATION CARTRIDGE USE
(see appendix B on page 5)
In areas where the water is very hard there might be an
output of minerals, noticeable as 'white dust'. To limit this
effect it is recommended to use a Demineralization Cartridge.
HOW IT WORKS:
The Demineralization Cartridge is filled with Mixed-Bed
De-ionizing Beads. Half of the beads have a positive
electrical charge while half of the beads have a negative
electrical charge. All minerals found in water have an
inherent electrical charge (some positive, some negative).
Minerals with a positive charge will attached themselves to
the negative beads while minerals with a negative charge
will attach themselves to the positive beads.In this way,
minerals are removed from the water as it passes through the
cartridge prior to entering the humidifier or the room being
humidified.
E) HOW TO PUT THE CARTRIDGES
(See appendix B on page 5)
• Remove the cartridge from the polybag
• Screw firmly onto the humidifier Water Tank Cap using the
threads provided on the cap (the cartridge will reside inside
the water tank)
• Fill water tank.
• Turn on Humidifier.
Cartridge will be effective ~60 days depending on local
water quality
10
All manuals and user guides at all-guides.com
CARE AND CLEANING INSTRUCTIONS
CLEANING
A) DAILY
(See appendix D on page 6)
• Pull the power plug before cleaning, Remove the tank cap
and Empty the residual water before cleaning.
• Lift the Water Tank from the Base and empty all water from
the reservoir. Remove the Tank Cap and drain any water from
the Water Tank. Wipe it clean with a soft, damp cloth. Rinse
the Water Tank with lukewarm water after each use (Fig. 5).
• DO NOT immerse the Base in water. Gently wipe the reservoir
with a soft, clean, wet cloth.
• DO NOT use detergent to clean any water-containing parts
of the humidifier. Detergents and the film they leave behind
can affect the output of the humidifier. DO NOT use abrasive
cleansers or brushes.
• DO NOT leave water in the Water Tank or reservoir when the
unit is not in use as it may result in the buildup of mineral
deposits and bacteria that can inhibit the output efficiency of
the humidifier. Please note that if water remains in the Water
Tank for more than a day or two, bacteria growth is possible.
CLEANING (See appendix E on page 7)
B) WEEKLY
• Pull the power plug before cleaning, Remove the tank cap
and Empty the residual water before cleaning.
• Thoroughly clean humidifier every week using a solution of
bleach and water (one teaspoon of bleach in one gallon of
water). Fill the Water Tank partially with this solution, let
stand twenty (20) minutes, shaking vigorously every few
minutes. Drain and rinse with clean water until the bleach
smell is gone (Fig. 6).
• Wipe the reservoir with a soft cloth dampened in the
solution. Rinse area thoroughly before proceeding.
•
If mineral deposits are evident around the Nebulizer, clean
the surface with a soft, clean cloth and a small amount of
undiluted white vinegar. If necessary for removal of mineral
deposits, mix a solution of 50% white vinegar and 50% water
and fill the Base with enough solution to cover the Nebulizer.
Rinse out the reservoir and wipe clean.
Do not touch Nebulizer or the Water Sensor with bare fingers
as any fingerprints or residue can reduce mist output. Do
not immerse the Base in water.
• All surfaces should be thoroughly cleaned with water prior to
reuse. Please dry the appliance with another cloth before use.
STORAGE
Follow cleaning instruction, discard cartridge and dry
product thoroughly.
DISPOSAL
Please do not dispose of this product in the household
waste at the end of its useful life. Disposal can take place
at your local retailer or at appropriate collection points
provided.
This regulation is valid only in EU member states.
CONDITION OF SALE
As a condition of sale, the purchaser assumes responsibility for
the proper use and care of this appliance in accordance with these
printed instructions. The purchaser or user must judge himself or
herself when to use the appliance and the length or use.
TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
Power Switch is set to "On"
1. Unit not plugged in
and Power Light is off
2. No power at outlet
Little or no mist is produced
1. No water in tank
2. Unit is not level
3. Mineral deposits on Nebulizer
4. Water Tank was washed with
detergent
5. Water level too low
6. Demineralization Cartridge
is clogged
7. Nebulizer or fan not functioning
Condensation forms around
1. Mist intensity is set too high for room
humidifier or windows
size or preexisting humidity level
White Dust Accumulation
1. Hard water used
2. Demineralization Cartridge needs
replacement
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR
HUMIDIFIER PLEASE SEE WARRANTY FOR INSTRUCTIONS.
PLEASE DO NOT ATTEMPT TO REPAIR THE HUMIDIFIER
YOURSELF. DOING SO WILL VOID THE WARRANTY AND
COULD CAUSE DAMAGE OR PERSONAL INJURY.
This product carries the CE mark and is manufactured in
conformity with the Electromagnetic Directive 2004/108/EC,
the Low Voltage Directive 2006/95/EC and the RoHS Directive
2011/65/EU.
Technical specifications are subject to change.
VH5000AE
220-240V ~ 50-60Hz
21W
CORRECTIVE ACTION
Plug unit in.
Check circuits, fuses, try a different
outlet.
Fill Water Tank.
Place on a level surface.
Clean Nebulizer per instructions.
Rinse thoroughly with clean water.
Wipe dry.
Add water to Water Tank.
Remove Cartridge and restart machine.
If mist resumes, replace with a new
Cartridge (Model CH5000-DEM).
See Guarantee.
Reduce output level or shut off
humidifier.
Use distilled water or a Demineralization
Cartridge.
Replace Demineralization Cartridge
(Model CH5000-DEM).
11