Warning Function
When indicator b lights up on display 3 and indication
4 flashes above button 10, the measurement must be
restarted. Remove the measuring tool from the wall and
place it on the base material at a different location.
When indicator b flashes on display 3, send the
measuring tool in the provided protective pouch to an
authorised customer services agent.
Recalibration
When measuring indicator i indicates a continuously
high amplitude in the operating mode "Metal", even
though there is no metal object near the measuring
tool, the measuring tool can be manually recalibrated.
• Switch the measuring tool off.
• Remove all objects near the measuring tool that
could be detected, including your wrist watch or
rings made of metal, and hold the measuring tool
up.
Pay attention that battery indicator h indicates at
least 1/3 capacity:
Hold the measuring tool in such a manner that the
type plate 13 faces toward the ground. Avoid bright
light sources or direct sunlight from shining on the
area 12 and 13, without covering off this area.
• Press and hold buttons 5 and 7 until the illuminated
ring 1 lights up red. Then release both buttons.
• When the calibration was successful, the measuring
tool will automatically start after a few seconds, and
will be ready for operation again.
Note: If the measuring tool does not automatically
start, repeat the recalibration. If the measuring tool
still does not start, send it in the provided protective
pouch to an authorised customer services agent.
Maintenance and Cleaning
❏ Check the measuring tool each time before
use. In case of visible damage or loose compo-
nents inside the measuring tool, safe function can
no longer be ensured.
Keep the measuring tool clean and dry at all times to
ensure proper and safe working.
Do not immerse the measuring tool in water or other
fluids.
Wipe away debris or contamination with a dry, soft
cloth. Do not use cleaning agents or solvents.
In order not to affect the measuring function,
decals/stickers or name plates, especially metal ones,
may not be attached in the sensor area 12 on the
front or back side of the measuring tool.
Do not remove the contact pads 11 on the backside
of the measuring tool.
If the measuring tool should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by a Würth masterService. Do
not open the measuring tool yourself.
In all correspondence and spare parts orders, please
always include the article number given on the type
plate of the measuring tool.
Store and transport the measuring tool only in the
supplied protective pouch.
In case of repairs, send in the measuring tool packed
in its protective pouch 17.
The current spare parts list of this measuring tool can
be found on the Internet under
"http://www.wuerth.com/partsmanager"
or be requested from the next Würth branch office.
Guarantee
For this Würth measuring tool, we provide a guaran-
tee according to statutory/country-specific regulations
from the date of purchase (verified by invoice or deliv-
ery document). Damage that has occurred will be cor-
rected by replacement or repair.
Damage caused by normal wear, overloading or
improper handling is excluded from the guarantee.
Claims can only be accepted if the measuring tool is
sent undisassembled to a Würth branch office, your
Würth sales representative or a customer service
agent for Würth power tools.
Disposal
Measuring tools, accessories and packaging should
be sorted for environmental-friendly recycling.
Do not dispose of measuring tools and batteries/
rechargeable batteries into household waste!
Only for EC countries:
According to the European Guideline
2002/96/EC, measuring tools that are no
longer usable, and according to the Euro-
pean Guideline 2006/66/EC, defective or
used battery packs/batteries, must be col-
lected separately and disposed of in an
environmentally correct manner.
Subject to change without notice.
16