telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that came with the product.
NOTE:
This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell
certified service technicians.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
3. Keep the #2 Phillips screwdriver ready.
4. Remove the storage controller card.
NOTE:
You must remove the storage controller card to replace a faulty storage controller card or service other
components inside the system.
Steps
1. Align the slots on the storage controller card edge with the tabs on the support bracket.
CAUTION:
To prevent damage to the storage controller card, hold the card only by its edges.
2. Lower the storage controller card on to the connector on the system board.
3. Tighten the two retention screws on the hard-drive backplane or SSD backplane cable connector to secure the card on to
the system board.
Figure 66. Installing the storage controller card
1. retention screw (2)
3. tab on the PCIe extender or storage controller card
support bracket
Next steps
1. Install the following:
a. hard drives or SSDs
b. hard-drive backplane or SSD backplane
2. slot on the PCIe extender or storage controller card
4. standoff (2)
Instalación y extracción de componentes del sled