PULMIC INDUSTRIAL 35
FILTERS
This machine has the following filters:
•
Filling mouth filter (Ref. 9032).
•
Suction filter (Ref. 13990). It is located on the side of the tank and can
be removed for cleaning. After cleaning, it is reassembled in its housing
in its housing in the same way and original position.
•
The correct maintenance of the filters is the best guarantee for the proper
functioning of your backpack. Clean these filters periodically (every work
day) and replace them if damage.
NOZZLES
The electric sprayer is supplied with quality nozzles. The performance of
this equipment may be reduced if a nozzle with excessive wear or a non
recommended nozzle are used. Replace the nozzle when it present signs of
deterioration.
RECHARGE AND BATTERY MAINTENANCE
The battery is a very sensitive subjected to wear, to lengthen its life is
important to read the charging and maintenance recommendations.
To recharge the batteries, extract the battery from its housing by pressing
the release lever and moving the battery up (Ref. 13943) (see fig. 1), then
connect the charger (Ref. 13980) to the mains through its mains connection.
100 / 240vAC.
Next, you must connect the 21v plug. DC to the battery socket (Ref. 13943)
located on the rear side, then the green battery LED will start to blink,
indicating that the recharging process has begun.
Figure 1
— 12 —
www.gruposanz.es