Rimage 2000i™ User Guide
Diagnostic Tests
This section provides the information needed to access, select, and perform Rimage 2000i diagnostic tests. Before you begin,
make sure that the Rimage 2000i is not in an error state.
-
Important! Perform only the diagnostic tests provided below. Do not attempt to perform other diagnostic tests without the
assistance of a Rimage trained technician.
Access Diagnostic Test Mode
1.
Power on the Rimage 2000i.
2.
Allow the system to fully initialize.
Note: It can take up to 5 minutes for the Rimage 2000i to initialize.
3.
Press and hold the operator button until [BUTTON DIAGNOSTIC] displays on the operator panel.
Note: Other status messages display on the operator panel while you press the operator button. Do not release the
button until [BUTTON DIAGNOSTIC] displays on the operator panel.
4.
Release the operator button. The Rimage 2000i is in diagnostic test mode.
Select a Diagnostic Test
1.
Press the operator button the same number of times as the test number, holding the button in on the last press to start
the selected test.
For example, to start Diagnostic Test 3 (Calibrate Diagnostic), press the operator button three times and hold it in on the
third press.
Tip: To display each diagnostic test number and name, press the operator button at a rate that is slow enough to read
the test on the operator panel. If you hold the button too long, the test begins.
2.
Continue with the desired diagnostic test.
Diagnostic Test 3 – Calibrate Diagnostic Test
This test uses one disc to calibrate the distance from the lift arm home position to the supply bin.
1.
Access and select diagnostic test 3. Refer to
2.
Press the operator button three times and hold it in on the last press. [STARTING TEST RELEASE BUTTON] displays
on the operator panel.
3.
Release the operator button. [PLACE ONE DISC INTO SUPPLY BIN PRESS/REL to GO] displays on the operator panel.
4.
Place one disc into the supply bin.
n
n
Caution: Make sure that there is only one disc in the supply bin. If you attempt to perform this test with more than
one disc in the system, miscalibration will occur. Miscalibration can cause damage to the lift arm and recorders.
5.
Press and release the operator button.
•
The lift arm moves to the supply bin and picks up the disc.
•
The lift arm releases the disc into the supply bin.
•
The lift arm moves back to its home position above the printer tray.
•
The Rimage 2000i exits diagnostic test mode and the system restarts.
26
All manuals and user guides at all-guides.com
Access Diagnostic Test Mode
on page 26.
100763_M