DUCTED INSTALLATION ONLY
Note: Rooms with 10-foot ceiling require
flue extension model AEWC345
available from your local dealer. Discard
the upper flue supplied with the range
hood and replace it with the longer flue
extension.
1. Remove protective tape from blower outlet
before installing damper to hood with
(4) screws supplied and tape joint with
aluminum duct tape. Fig. 11.
2. Run 8-inch diameter metal ductwork to
the outside location.
3. Install an appropriate wall or roof cap with
damper to exhaust the air to the outside.
4. Tape all duct joints with aluminum duct
tape.
5. Plug power cord into wall outlet.
6. Install upper and lower decorative flues
onto the range hood. Fig. 12.
- Vents are concealed on 8-foot
ceilings.
- Vents are exposed on 9-foot
ceilings.
7. Secure upper flue to flue mounting bracket
with (2) 3.9 x 6 mm screws. Fig. 13.
8-INCH DIA.
METAL DUCT