Beninca CP.RI624N Manual De Instrucciones página 12

Ocultar thumbs Ver también para CP.RI624N:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
With braking enabled (SLD logic: ON), braking will start at end of time preset with TM1 and TM2.
The preset time should therefore be lower than the real stroke of the operator. For example, with a 20s stroke, preset 17s to start
the braking phase, 3s in advance with respect to end of movement.
The speed of the motor during braking is determined by the SLDS parameter value.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or
IbL
transmitter impulse has no effect during the opening phase.
Off: condominium function disabled.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening
SCL
phase the intervention of the photocell causes automatic closing
after 3 s. Active only with TCA:ON.
Off: rapid closing disabled.
Enables or disables slowing.
Sld
On: Slowing active.
Off: Slowing excluded.
Selects the operating mode of the "Step by step button" and of the
transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor
PRE
starts.
Off: Pre-blinking disabled.
The lock function is enabled or disabled.
On: Lock function enabled. After the activation of closure limit switch-
Blc
es the control unit delays the stop by approx. 0.5s in order to allow a
better resting of the gate against the stoppers.
Off: Lock function disabled.
Selects the mode of the OPEN input
On: OPEN input with CLOCK function.
CLOC
To be used for connection to a timer for timed opening/closing. (Con-
tact CLOSED- gate open, Contact open, normal operation).
Off: OPEN input with OPEN function
Enables or disables Man present function.
On: Man Present operation.
htr
The OPEN/CLOSE buttons must be held down during the whole
manoeuvre.
Off: Automatic operation.
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vac/O,5A max.
Before each opening manoeuvre the power supply is interrupted for
mloc
the time set by the parameter TLOC.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vac for the time
set by the parameter TLOC.
Select the 1/2 motors operating mode:
1mot
On: Only motor 1 operating.
Off: Both motors operating.
12
ADJUSTMENT OF BRAKING
FUNCTION
Settable values
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)

Publicidad

Tabla de contenido
loading

Tabla de contenido