Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
2. Put the batteries inside the slot, must be corresponding to the signs of "+" and "-" on the remote control.
3. If for long time no using the device, take out the batteries.
4. To prevent environmental pollution, take out the used batteries and dispose safety and appropriately.
To operate the device, aim the remote controller at the signal receptor. The remote controller will operate the device at distance 5
meters when pointing at signal receptor of the device.

PROTECTIVE DEVICES

The protective device may trip and stop the appliance in the cases listed below:
1. at cooling mode: indoor air temperature is over 43°C (109°F)
2. at cooling mode: room temperature is below 15°C (59°F)
3. at dehumidifying mode: room temperature is below 15°C (59°F).
If the device runs in cooling "K" or dehumidify "L" mode with door or window opened for a long time when relative humidity is above
80%, dew may drip down from the outlet.
The protective device will work in the following cases:
1. Restarting the device immediately after stopping work or changing the selected mode while working, you must wait 3 minutes.
2. If the plug has been removed, after restarting the device will return to the original mode, all timer's setting must be set again.
REMARK: there is condensing water recycling hidden within this unit. The condensing water is partly kept recycling between the
condenser and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) lights on to
remind draining water. Please cut off the power supply, move the appliance to a suitable place, remove the drain plug, drain water
completely. After the drain, re-install the plug, or the appliance may leak and make your room wet.
If the appliance is placed in a position admitting drain water, you also can connect the pipe to the drain hole to drain out the water.
Drain pipe is added to kit, inner diameter 9mm , outer diameter 12mm, material: PVC.
Troubleshooting
1) Trouble: Do not work.
Analysis:
a) maybe the protector trip or fuse is blown, please wait for 3 minutes and start again, protector device may be preventing device
from working.
c) maybe batteries in the remote controller are exhausted.
d) maybe the plug is not properly plugged in.
2) Trouble: works for a short time only
Analysis:
a) if the set temperature is close to room temperature, you can lower the set temperature.
b) maybe air outlet is blocked by obstacle. Take the obstacle away.
3) Trouble: Works but not cools
Analysis:
a) maybe door or window are open.
b) maybe in close distance there is another appliance heat-working like heater or lamp, etc.
c) the air filter is dirty, please clean it.
d) air outlet or intake is blocked.
f) set temperature is too high.
4) Trouble: Water leak during moving.
Analysis:
a) drain the condensate before moving.
b) to avoid water leakage, please locate the device on flat ground.
5) Trouble: Do not work and water full indicator "E4"
Analysis:
a) pull out rubber plug to drain water.
b) if it is often in this state, please contact qualified service technical.
Troubleshooting
6) Trouble: Device fails to start up.
Analysis:
a) maybe not plugged. So, plug in it.
b) maybe plug or socket damages. Replace by service provider.
c) maybe fuse broken. Replace the fuse by service provider (specification: 3,15A/250VAC).
7) Trouble: Device automatically stops.
Analysis:
a) timing shut down or set temperature reached. Restart it or wait for auto-switch.
8

Publicidad

Tabla de contenido
loading

Tabla de contenido