2.
Install adapter
A. 1/2" rigid gas supply
pipe
B. Use pipe-joint
compound.
C. 1/2" NPT adapter
D. Do not use pipe-
joint compound.
E. Flexible gas
connector
Install the adapter on the 1/2" rigid gas supply pipe using
pipe-joint compound.
NOTE: For propane gas connections, you must use pipe-joint
compound resistant to action of propane gas. Do not use
TEFLON
tape.
®†
3.
Attach connector
Correct
Wrong
Attach the flexible gas connector to the 1/2" NPT adapter.
Do not use pipe-joint compound for this connection.
There should be a natural loop in the flexible gas connector.
The flexible gas connector must not be twisted, kinked, or
attached with any sharp bends.
4.
Open shut-off valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leak found.
TEFLON is a registered trademark of Chemours.
†®
A
B
C
D
E
Wrong
Wrong
B
A. Closed valve
B. Open valve
Connect Vent
1.
Connect vent to exhaust outlet
(27" (69 cm) model shown)
Connecting from front
(for closet or recessed
area)
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2.
Move washer/dryer to final location
Move washer/dryer to final location, taking care not to crush
or kink vent.
After washer/dryer is in place, remove corner posts and
cardboard from under washer/dryer.
Connecting
from rear
31