Primary filter replacement
Figure 14
1.
Vacuuming unit
2.
Locking lever
3.
Filter cage
4.
Primary filter
5.
Filter shaker housing
WARNING!
Check the vacuum cleaner class (L, M, H).
WARNING!
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
■
Use lever (2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
■
Remove the filter cage from the vacuum cleaner.
■
Remove the old filter by releasing the fixing clips.
■
Fit the new filter and secure it in the cage with special
clamps.
■
Dispose of the old filter according to the laws in force.
Replacing a primary filter with automatic filter shaker
WARNING!
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
■
After replacing the filter in the cage (3), install it in the
container again.
■
Reassemble vacuum unit (1) making sure filter cage (3)
fits into shaped housing (5) of the filter shaker.
■
Turn the power switch on and the vacuum unit will self-
centre automatically.
■
Use locking lever (2) to lock the vacuum unit in place.
01/2015
Replacing a primary filter with manual filter shaker
1.
Manual filter shaker knob
2.
Vacuuming unit
3.
Locking lever
4.
Filter cage
5.
Filter shaker housing
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
■
After having replaced and fitted the filter in the cage,
insert filter shaker cage (4) in the shaped seat (5) of the
filter shaker.
■
Position the manual filter shaker knob (1) in the middle.
■
Reassemble vacuum unit (2) complete with cage and
filter, in the vacuum container.
■
Check the filter shaker works properly and if necessary
adjust the position of the filter cage by turning the
vacuum unit.
■
Use locking lever (3) to lock the vacuum unit in place.
If necessary contact the manufacturer's Service Centre.
11
S2 / S3 / E-VAC2000 / BDC1330
Figure 15
WARNING!
GB
C343