SERVICING YOUR PURIFIER

Cleaning the Air Purifier
• Turn the air purifier off and unplug it before cleaning.
• The outside of the air purifier can be cleaned with a soft, dirt free, dampened cloth.
• The air inlet and outlet grills can be cleaned with a small dry, soft brush.
Fuse Replacement
The air purifier has a replaceable fuse in the power cord plug. If the air purifier
suddenly stops working, first try the steps in the Troubleshooting section. If the air
purifier is still not working, replace the fuse by following the instructions below:
• Grasp the plug and remove it from the receptacle or other outlet device. Do not unplug
by pulling on the cord.
• Open the fuse cover. Slide open the fuse access cover on top of the attachment plug
toward the plug blades.
• Remove the fuse carefully. A small tool such as a screwdriver may be useful to help pry
out the fuse.
• Risk of fire. Replace the fuse only with a 5 Amp, 125 Volt fuse.
• Close the fuse cover. Slide closed the fuse access cover on top of the attachment plug.

TROUBLESHOOTING

Where To Find Your Model Number
• The air purifier model number, serial number, and electrical rating can be found on
the label on the bottom on the air purifier.
Replacement Filter Does Not Fit
• Check the model number on the filter and compare it to the table on page 4.
• Make sure no foreign objects are blocking the filter opening.
• Make sure that any packaging materials have been removed from the filter.
Air Purifier Will Not Turn On
• Be sure the air purifier is properly plugged into a 120V AC outlet.
• Check if a fuse has blown or if a circuit breaker has been tripped. First check both
the home's fuses and/or circuit breakers, then check the fuse in the air purifier's
power cord. If a circuit breaker has tripped or a fuse has blown, first try to
determine the root cause for the fault condition and correct the fault condition
before resetting circuit breakers or replacing fuses. If no fault can be found, try
replacing the fuse in the air purifier's power cord. If the fuse blows a second time,
discard the air purifier.