7
Technical Data of the On Line A 1000 Cartridge
Operating pressure
Water intake temperature
operation
Ambient tempera-
ture during
storage/transport
Filtration fl ow rate (acc. to JIS)
Minimum operating fl ow (acc. to NSF)
Working fl ow range and associated
pressure loss
Bed Volume
Weight (dry/wet)
Rated fi lter capacity
Chlorine reduction NSF 42
Particle retention NSF 42
Chlorine reduction DIN EN 14898
Filter system
(fi lter head with
fi lter cartridge)
Dimensions
Filter cartridge
(Width/Depth/
Height)
Installed dimen-
sions (vertical
installation with
wall mounting)
Operating position
Water inlet connection
Water outlet connection
10
ENGLISH
All manuals and user guides at all-guides.com
2 bar to max. 8.6 bar
4°C to 30°C
4°C to 30°C
–20°C to 50°C
2.5 L/min
1.9 L/min
30–180 L/h / 0.2–1.4 bar
0.23 L
0.4 kg/0.9 kg
10,000 L
Class I (50%)
Class I (0.5 μm)
Class 1 (>90%)
106 mm/92 mm/232 mm
86 mm/86 mm/224 mm
137 mm/122 mm/232 mm
Horizontal and vertical
G3/8"
G3/8"
8
Troubleshooting
A No water fl ow
Cause:
Water intake closed.
Troubleshooting:
Open the water intake at the upstream shut-off
valve or by closing the locking handle (2) on the
fi lter head (1).
B No or low water fl ow in spite of open water intake
Cause:
Mains pressure too low.
Troubleshooting:
Check mains pressure. If the fault continues,
check the fi lter system and fi lter cartridge and
replace if necessary.
Cause:
Filter head not mounted in direction of water
fl ow.
Troubleshooting:
Dismantle fi lter head and install in direction of
water fl ow (chapter 3.2).
C Leak
Cause:
Screwed connections not fi tted correctly.
Troubleshooting:
Check mains pressure. Check all screwed
connections in accordance with chapter 3.2.
D Incorrect display or incorrect settings on the electronic
cartridge exchange indicator with display
Cause:
Buttons pressed in wrong order or wrong
buttons pressed.
Troubleshooting:
Press and hold the RESET button for 8 seconds.