3.2
Step 2: Attaching the hoses
We recommend that you fi rst arrange all parts you need in
!
front of you. You will need a 3/8" or 1/2" supply which is also
connected to your kitchen tap (see fi g. 3).
Recommended for installation of the wall mount: two screws
(e.g. 5 mm in size) and two wall plugs (if necessary). Please use
appropriate screws and wall plugs for the type of wall.
Please follow the diagram below and the steps in the right order.
A a) Turn off the cold water supply.
b) Put the hose (1) in place.
c) Insert the appropriate gasket in the respective internal thread
of the two hose ends (3/8").
d) Now connect the correct end of the hose (1) to the fi lter head
inlet (3/8"). This is labelled "IN" (inlet) and marked with an
arrow. Make sure the gasket is seated correctly!
B Now connect the other end of the hose (1) to your cold water
tap, and make sure the gasket is correctly positioned! If your
(fi g. 3)
Cold water
supply
3/8"
or Adapter
A
All manuals and user guides at all-guides.com
Gasket (10)
Hose 1:
800 mm
cold water tap does not fi t the 3/8" connector on the hose (1),
use the supplied adapter if required. Please go to your nearest
supplier for adapters in other sizes.
C a) Put the hose (2) in place.
b) Put the correct gasket (3/8") into the nut of hose (2).
D Connect the correct end of hose (2) to the outlet on the fi lter
head, labelled with the "OUT" arrow.
E Place a suitable gasket into the nut of the hose, which is already
attached to the kitchen tap fi tting, and connect it to the other
end of the hose (2). If you cannot connect the end of the hose
(2) to the end of the hose on your tap fi tting, use the adapter
supplied.
The max. tightening torque for the G3/8" connections must
not exceed 14 Nm! Only hose connections with gaskets (10)
!
of original BRITA hoses may be used because hoses with
conical screw connections damage the connections of the
fi lter head and invalidate any warranty claims!
3/8"
3/8"
B
C
Gasket (10)
Hose 2:
3/8"
800 mm
or Adapter
ENGLISH
7